    User name adev

    Log entry time 06:26:47 on April 23, 2001

    Entry number 61096

    keyword=End_of_Run_3824
    ****************************
     Run Number: 3824
    End of Run Comment:
    RunType=Other,Tar=LH2-15cm,Rad=out,comment=Hyper-White Scan,mode=singles,Lmom=1.0023,Rmom=1.0023,Ene=3994,Angle_R=44.3,Angle_L=44.3
    
    
    Time of run = 18.249023 min
    Av. current (on 3x) = 40.349009 uA
    Av. current (on 1x) = 80.688062 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   88.3487  |   44.1798  |   77.9410
    up-down    (mC)|   -0.8610  |   88.4090  |   -1.9365
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 13063.919 Hz  |    323773.0 /mC  |  816.495 Hz  |  14304226  |    16   |    161906.5 /mC
        2      | 690.14561 Hz  |     17104.4 /mC  |  690.146 Hz  |    755669  |     1   |      8553.3 /mC
        3      | 13177.155 Hz  |    326579.4 /mC  |  823.572 Hz  |  14428212  |    16   |    163309.8 /mC
        4      | 835.43923 Hz  |     20705.3 /mC  |  835.439 Hz  |    914757  |     1   |     10353.9 /mC
        5      | 27.037063 Hz  |       670.1 /mC  |    0.000 Hz  |     29604  | 65535   |       335.1 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 16.865742 Hz  |       418.0 /mC  |    0.000 Hz  | 18467.0  | 65535   |       209.0 /mC
        8    | 1024.0 Hz  |     25378.6 /mC  |    0.016 Hz  |   1121220  | 65535   |     12690.8 /mC
        output                      1869.337 Hz
    Av. deadtime from accepted triggers = 0.4095
    Av. deadtime from gated scalers = 0.4118
    Accepted triggers  = 2046814.00000
    Rate of Left Arm Pulser for electronic DT  = 10.171321
    Rate of Right Arm Pulser for electronic DT  = 10.227945
    Rate of Left Arm Pulser&trig for electronic DT  = 10.166754
    Rate of Right Arm Pulser&trig for electronic DT  = 10.227031
    Left Arm Electronic DT  = 0.00044895394
    Right Arm Electronic DT  = 8.9293687e-05
    Rate of Left Strobe  = 61550.529
    Rate of Right Arm Strobe  = 52158.795
        Signal     |    Charge   (C)   
       upstream    |    0.0879182     
       upstream 3x |    0.0883843     
       upstream 10x|    0.0769727     
      downstream   |    0.0887792   
     downstream 3x |    -0.0000247   
     downstream 10x|    0.0789092    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 3824 at Mon Apr 23 06:26:33 EDT 2001
    Right Arm D1 momentum                    : 0.9823
    Right Arm arm angle                      : 44.3025
    Left Arm D1 momentum                      : 0.982296
    Left Arm arm angle                        : 44.2739
    Tiefenbach Hall A energy                : 4000.29
    Right Arm arm mispointing (HPT)          : -0.26026
    Left Arm arm mispointing (HPT)            : 3.7165
    Right Arm Q1 power supply current        : 738.535
    Right Arm Q1 momentum                    : 0.982179
    Right Arm Q1 gauss meter                 : -0.018492
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 422.592
    Right Arm Q2 momentum                    : 0.981934
    Right Arm Q2 gauss meter                 : 0.2223
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 335.075
    Right Arm D1 momentum                    : 0.9823
    Right Arm D1 NMR                         : 0.36452
    Right Arm Q3 power supply current        : 390.83
    Right Arm Q3 momentum                    : 0.982209
    Right Arm Q3 gauss meter                 : 0.17511
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 738.71
    Left Arm Q1 momentum                      : 0.981894
    Left Arm Q1 gauss meter                   : -0.06254
    Left Arm Q1 power supply polarity         : 0
    Left Arm Q2 power supply current          : 422.994
    Left Arm Q2 momentum                      : 0.982174
    Left Arm Q2 gauss meter                   : 0.2236
    Left Arm Q2 power supply polarity         : 1
    Left Arm D1 power supply current          : 327.038
    Left Arm D1 momentum                      : 0.982297
    Left Arm D1 NMR                           : 0.363681
    Left Arm Q3 power supply current          : 391.099
    Left Arm Q3 momentum                      : 0.982369
    Left Arm Q3 gauss meter                   : -0.1951
    Left Arm Q3 power supply polarity         : 1
    Average current of the two cavities     : 86.9872
    Current on Unser monitor                : 94.0283
    Current on Upstream bcm                 : 86.8091
    Current on Downstream bcm               : 87.1653
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 87.7358
    MBSY1c Hall A Beam energy               : 4007.96
    MBSY1c magnet current (amp)             : 167.034
    MBSY1c Bdl                              : 1.00019e+06
    MBSY3c Hall C Beam energy               : 2423.72
    Tiefenbach Hall A energy                : 4000.29
    Tiefenbach Hall C energy                : 2418.01
    Delta(E)/E width (MV_AI_DXWID)          : 1.71789
    IPM1C12.XPOS                            : 0.00627899
    IPM1H04A.XPOS                           : 1.22348
    IPM1H04A.YPOS                           : 0.460727
    IPM1H04B.XPOS                           : 1.11966
    IPM1H04B.YPOS                           : 0.000295585
    Right Arm Arm Collimator                 : 0.865381
    Left Arm Arm Collimator                   : 0.868555
     HacR_HPM_LVDT:VALr                     : -2264
     HacR_VPM_LVDT:VALr                     : 760
     HacR_HPE1313A:0_Ch58                   : -0.519531
     HacR_HPE1313A:0_Ch55                   : 22.5098
     HacR_HPE1313A:0_Ch54                   : -0.940918
     HacR_alignROLL                         : -0.461458
     HacR_alignPITCH                        : -0.0343494
     HacR_alignHPT                          : -0.260291
     HacL_HPM_LVDT:VALr                     : -6707
     HacL_VPM_LVDT:VALr                     : -205
     HacL_HPE1313A:0_Ch58                   : -0.234375
     HacL_HPE1313A:0_Ch55                   : 23.6816
     HacL_HPE1313A:0_Ch54                   : -0.276367
     HacL_alignROLL                         : 0.0869881
     HacL_alignPITCH                        : -0.0350814
     HacL_alignHPT                          : 3.71934
    haBDSPOS                                 : 4.6174e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 63.5
    haL3_Fan_frequency_R                     : 25
    haH2_P_Fill_Target_R                     : 20.41
    haH2_P_Exhaust_R                         : 20.74
    haH2_P_Fill_Bottle_R                     : 20.45
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 18.74
    haD2_P_Fill_Bottle_R                     : 38.69
    haD2_DP_Fill_Exhaust_R                   : 0.0743
    haSC200_6_Sensor_1_R                     : 242.2
    haSC200_6_Sensor_2_R                     : 35.18
    haSC200_6_Sensor_3_R                     : 43.97
    haSC200_6_Sensor_4_R                     : 41.99
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19.01
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.24
    haITC502_4_Sensor_1_R                    : 149.5
    haITC502_4_Sensor_2_R                    : 19.2
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 90.63
    haITC502_5_Sensor_2_R                    : 26.5
    haITC502_5_Sensor_3_R                    : 2988.6
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 28.25
    Right Arm Arm Collimator                 : 0.86543
    Left Arm Arm Collimator                   : 0.868604
    Wien angle                               : 32.9201
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 739.73
    Wien field                               : 21.203
    Laser attenuation Hall A                 : 322
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF