    User name adev

    Log entry time 12:49:51 on April 23, 2001

    Entry number 61117

    keyword=End_of_Run_3830
    ****************************
     Run Number: 3830
    End of Run Comment:
    RunType=Cosmic,Tar=absence,Rad=out,comment=Hyper-White Scan,mode=singles,Lmom=0.9823,Rmom=0.450,Ene=3994,Angle_R=44.3,Angle_L=14.0
    
    Time of run = 10.139339 min
    Av. current (on 3x) = 0.033697134 uA
    Av. current (on 1x) = 0.082023755 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    0.0499  |    0.0205  |    0.0760
    up-down    (mC)|    0.0214  |    0.0685  |    0.0007
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 161.56543 Hz  |   4794634.1 /mC  |  161.565 Hz  |     98290  |     1   |   1969739.5 /mC
        2      | 12.482733 Hz  |    370439.0 /mC  |   12.483 Hz  |      7594  |     1   |    152184.4 /mC
        3      | 597.51757 Hz  |  17732000.0 /mC  |  597.518 Hz  |    363506  |     1   |   7284689.4 /mC
        4      | 125.0328 Hz  |   3710487.8 /mC  |  125.033 Hz  |     76065  |     1   |   1524348.7 /mC
        5      | 10.257079 Hz  |    304390.2 /mC  |    0.000 Hz  |      6240  | 65535   |    125050.1 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 0.077257 Hz  |      2292.7 /mC  |    0.000 Hz  | 46.999925  | 65535   |       941.9 /mC
        8    | 1024.0 Hz  |  30388341.0 /mC  |    0.016 Hz  |    622961  | 65535   |  12484188.0 /mC
        output                       374.780 Hz
    Av. deadtime from accepted triggers = 0.5820
    Av. deadtime from gated scalers = 0.3647
    Accepted triggers  = 228001.00000
    Rate of Left Arm Pulser for electronic DT  = 10.179822
    Rate of Right Arm Pulser for electronic DT  = 10.20941
    Rate of Left Arm Pulser&trig for electronic DT  = 10.179822
    Rate of Right Arm Pulser&trig for electronic DT  = 10.20941
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 2147.2553
    Rate of Right Arm Strobe  = 1798.827
        Signal     |    Charge   (C)   
       upstream    |    0.0000606     
       upstream 3x |    0.0000548     
       upstream 10x|    0.0000763     
      downstream   |    0.0000392   
     downstream 3x |    -0.0000137   
     downstream 10x|    0.0000756    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 3830 at Mon Apr 23 12:49:41 EDT 2001
    Right Arm D1 momentum                    : 0.45
    Right Arm arm angle                      : 25.0141
    Left Arm D1 momentum                      : 0.98229
    Left Arm arm angle                        : 12.4747
    Tiefenbach Hall A energy                : 4000.27
    Right Arm arm mispointing (HPT)          : -2.05206
    Left Arm arm mispointing (HPT)            : 3.7657
    Right Arm Q1 power supply current        : 338.415
    Right Arm Q1 momentum                    : 0.450059
    Right Arm Q1 gauss meter                 : -0.008503
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 193.847
    Right Arm Q2 momentum                    : 0.450421
    Right Arm Q2 gauss meter                 : 0.10222
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 153.245
    Right Arm D1 momentum                    : 0.45
    Right Arm D1 NMR                         : 0.16699
    Right Arm Q3 power supply current        : 179.306
    Right Arm Q3 momentum                    : 0.449918
    Right Arm Q3 gauss meter                 : 0.08043
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 739.13
    Left Arm Q1 momentum                      : 0.982452
    Left Arm Q1 gauss meter                   : -0.06257
    Left Arm Q1 power supply polarity         : 0
    Left Arm Q2 power supply current          : 422.926
    Left Arm Q2 momentum                      : 0.98218
    Left Arm Q2 gauss meter                   : 0.2235
    Left Arm Q2 power supply polarity         : 1
    Left Arm D1 power supply current          : 327.035
    Left Arm D1 momentum                      : 0.98229
    Left Arm D1 NMR                           : 0.363678
    Left Arm Q3 power supply current          : 391.094
    Left Arm Q3 momentum                      : 0.982219
    Left Arm Q3 gauss meter                   : -0.19509
    Left Arm Q3 power supply polarity         : 1
    Average current of the two cavities     : 1.10296
    Current on Unser monitor                : 8.34177
    Current on Upstream bcm                 : 1.10094
    Current on Downstream bcm               : 1.10499
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 63.823
    MBSY1c Hall A Beam energy               : 4007.96
    MBSY1c magnet current (amp)             : 167.034
    MBSY1c Bdl                              : 1.00019e+06
    MBSY3c Hall C Beam energy               : 2423.72
    Tiefenbach Hall A energy                : 4000.27
    Tiefenbach Hall C energy                : 2418.18
    Delta(E)/E width (MV_AI_DXWID)          : 3.03527
    IPM1C12.XPOS                            : 0.74192
    IPM1H04A.XPOS                           : 1.24388
    IPM1H04A.YPOS                           : 0.971412
    IPM1H04B.XPOS                           : 1.15022
    IPM1H04B.YPOS                           : 0.587707
    Right Arm Arm Collimator                 : 0.61499
    Left Arm Arm Collimator                   : 0.616992
     HacR_HPM_LVDT:VALr                     : -691
     HacR_VPM_LVDT:VALr                     : -73
     HacR_HPE1313A:0_Ch58                   : -0.536621
     HacR_HPE1313A:0_Ch55                   : 22.5586
     HacR_HPE1313A:0_Ch54                   : -0.798828
     HacR_alignROLL                         : -0.317953
     HacR_alignPITCH                        : -0.0187059
     HacR_alignHPT                          : -2.05318
     HacL_HPM_LVDT:VALr                     : -6886
     HacL_VPM_LVDT:VALr                     : 1488
     HacL_HPE1313A:0_Ch58                   : -0.229004
     HacL_HPE1313A:0_Ch55                   : 23.9258
     HacL_HPE1313A:0_Ch54                   : 0.0668945
     HacL_alignROLL                         : 0.405689
     HacL_alignPITCH                        : -0.0610183
     HacL_alignHPT                          : 3.76637
    haBDSPOS                                 : 4.6174e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 67
    haL3_Fan_frequency_R                     : 24.5
    haH2_P_Fill_Target_R                     : 22.18
    haH2_P_Exhaust_R                         : 22.49
    haH2_P_Fill_Bottle_R                     : 22.23
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 19.99
    haD2_P_Fill_Bottle_R                     : 41.15
    haD2_DP_Fill_Exhaust_R                   : 0.0742
    haSC200_6_Sensor_1_R                     : 242.63
    haSC200_6_Sensor_2_R                     : 35.55
    haSC200_6_Sensor_3_R                     : 44.22
    haSC200_6_Sensor_4_R                     : 42.11
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.01
    haITC502_4_Sensor_1_R                    : 152.6
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 295.22
    haITC502_5_Sensor_2_R                    : 0
    haITC502_5_Sensor_3_R                    : 0
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 28.24
    Right Arm Arm Collimator                 : 0.61499
    Left Arm Arm Collimator                   : 0.617041
    Wien angle                               : 32.9201
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 739.73
    Wien field                               : 21.203
    Laser attenuation Hall A                 : 70
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF