User name adev
Log entry time 12:57:50 on April 23, 2001
Entry number 61121
keyword=Start_Run_3832_RunType=Other,Tar=LH2-15cm,Rad=out,comment=Hyper-White
Beginning-of-run EPICS data for Run Number 3832 at Mon Apr 23 12:57:40 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180,ps2=1,ps3=720,ps4=150,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 338.415
Right Arm Q1 momentum : 0.450059
Right Arm Q1 gauss meter : -0.008503
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 193.713
Right Arm Q2 momentum : 0.450112
Right Arm Q2 gauss meter : 0.1022
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 153.29
Right Arm D1 momentum : 0.449999
Right Arm D1 NMR : 0.166989
Right Arm Q3 power supply current : 179.306
Right Arm Q3 momentum : 0.450622
Right Arm Q3 gauss meter : 0.08041
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 739.13
Left Arm Q1 momentum : 0.982452
Left Arm Q1 gauss meter : -0.06258
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 423.087
Left Arm Q2 momentum : 0.982551
Left Arm Q2 gauss meter : 0.2235
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 327.039
Left Arm D1 momentum : 0.982289
Left Arm D1 NMR : 0.363678
Left Arm Q3 power supply current : 391.129
Left Arm Q3 momentum : 0.982443
Left Arm Q3 gauss meter : -0.19508
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 1.33719
Current on Unser monitor : 7.80258
Current on Upstream bcm : 1.33582
Current on Downstream bcm : 1.33857
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 64.6378
Beam energy : 4007.96
MBSY1c magnet current (amp) : 167.034
Radiator 5V Linear Supply : 5.03541
Radiator Encoder : 0.163614
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 68
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 242.5
haSC200_6_Sensor_2_R : 35.46
haSC200_6_Sensor_3_R : 44.17
haSC200_6_Sensor_4_R : 42.06
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 152.6
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 295.1
haITC502_5_Sensor_2_R : 0
haITC502_5_Sensor_3_R : 903.5
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.23
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -691
HacR_VPM_LVDT:VALr : -82
HacR_HPE1313A:0_Ch58 : -0.536621
HacR_HPE1313A:0_Ch55 : 22.5098
HacR_HPE1313A:0_Ch54 : -0.797852
HacR_alignROLL : -0.317025
HacR_alignPITCH : -0.0190883
HacR_alignHPT : -2.05259
HacL_HPM_LVDT:VALr : -6881
HacL_VPM_LVDT:VALr : 1493
HacL_HPE1313A:0_Ch58 : -0.229004
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : 0.065918
HacL_alignROLL : 0.404681
HacL_alignPITCH : -0.0609455
HacL_alignHPT : 3.76127
Right Arm Angle Floor Angle : 24.5
Right Arm Angle Vernier : 52.6
Right Arm Scattering Angle : 25.0141
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31.1
Left Arm Scattering Angle : 12.4748
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 70
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88