User name adev
Log entry time 18:04:25 on April 23, 2001
Entry number 61147
keyword=Start_Run_3841_RunType=Other,Tar=LH2-15cm,Rad=out,comment=Hyper-White
Beginning-of-run EPICS data for Run Number 3841 at Mon Apr 23 18:04:11 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1000,ps2=1,ps3=1000,ps4=1000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 338.31
Right Arm Q1 momentum : 0.449919
Right Arm Q1 gauss meter : -0.008506
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 193.559
Right Arm Q2 momentum : 0.449753
Right Arm Q2 gauss meter : 0.10223
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 153.808
Right Arm D1 momentum : 0.449998
Right Arm D1 NMR : 0.166989
Right Arm Q3 power supply current : 179.052
Right Arm Q3 momentum : 0.449982
Right Arm Q3 gauss meter : 0.08035
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1880.83
Left Arm Q1 momentum : 2.5
Left Arm Q1 gauss meter : -0.15902
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1076.48
Left Arm Q2 momentum : 2.49995
Left Arm Q2 gauss meter : 0.567
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 860.042
Left Arm D1 momentum : 2.49431
Left Arm D1 NMR : 0.923197
Left Arm Q3 power supply current : 995.283
Left Arm Q3 momentum : 2.49996
Left Arm Q3 gauss meter : -0.496
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 3.45285
Current on Unser monitor : 10.5153
Current on Upstream bcm : 3.44817
Current on Downstream bcm : 3.45754
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 71.2577
Beam energy : 4007.96
MBSY1c magnet current (amp) : 167.034
Radiator 5V Linear Supply : 5.02808
Radiator Encoder : 0.163614
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 63
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 242.01
haSC200_6_Sensor_2_R : 35.41
haSC200_6_Sensor_3_R : 43.94
haSC200_6_Sensor_4_R : 41.99
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 154.4
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 0
haITC502_5_Sensor_2_R : 0
haITC502_5_Sensor_3_R : 39.9
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.18
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -667
HacR_VPM_LVDT:VALr : -77
HacR_HPE1313A:0_Ch58 : -0.536133
HacR_HPE1313A:0_Ch55 : 22.3145
HacR_HPE1313A:0_Ch54 : -0.791992
HacR_alignROLL : -0.311779
HacR_alignPITCH : -0.0197865
HacR_alignHPT : -2.08245
HacL_HPM_LVDT:VALr : -6836
HacL_VPM_LVDT:VALr : 1517
HacL_HPE1313A:0_Ch58 : -0.227051
HacL_HPE1313A:0_Ch55 : 23.6816
HacL_HPE1313A:0_Ch54 : 0.0615234
HacL_alignROLL : 0.400184
HacL_alignPITCH : -0.0624008
HacL_alignHPT : 3.71314
Right Arm Angle Floor Angle : 24.5
Right Arm Angle Vernier : 52.6
Right Arm Scattering Angle : 25.0143
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31.1
Left Arm Scattering Angle : 12.4751
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 158
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88