User name adev
Log entry time 01:06:17 on April 24, 2001
Entry number 61190
keyword=Start_Run_3854_RunType=Other,Tar=9foil-12C,Rad=out,comment=Junk,mode=singles,Lmom=0.9823,Rmom=0.450,Ene=3994,Angle_R=25,Angle_L=14.0
Beginning-of-run EPICS data for Run Number 3854 at Tue Apr 24 01:06:06 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=10,ps2=10,ps3=30,ps4=300,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1879.89
Right Arm Q1 momentum : 2.50006
Right Arm Q1 gauss meter : -0.04673
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1075.88
Right Arm Q2 momentum : 2.4999
Right Arm Q2 gauss meter : 0.5652
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 918.523
Right Arm D1 momentum : 2.36707
Right Arm D1 NMR : 0.87839
Right Arm Q3 power supply current : 994.661
Right Arm Q3 momentum : 2.49972
Right Arm Q3 gauss meter : 0.4462
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1880.8
Left Arm Q1 momentum : 2.49996
Left Arm Q1 gauss meter : -0.159
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1076.38
Left Arm Q2 momentum : 2.49971
Left Arm Q2 gauss meter : 0.5676
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 861.227
Left Arm D1 momentum : 2.50001
Left Arm D1 NMR : 0.925312
Left Arm Q3 power supply current : 995.268
Left Arm Q3 momentum : 2.49993
Left Arm Q3 gauss meter : -0.4966
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0619087
Current on Unser monitor : 7.35588
Current on Upstream bcm : 0.0636073
Current on Downstream bcm : 0.0602101
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 66.0559
Beam energy : 4007.96
MBSY1c magnet current (amp) : 167.034
Radiator 5V Linear Supply : 5.02564
Radiator Encoder : 0.161172
haBDSPOS : 2.9824e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 66
haL3_Fan_frequency_R : 37
haSC200_6_Sensor_1_R : 242.25
haSC200_6_Sensor_2_R : 35.5
haSC200_6_Sensor_3_R : 44.09
haSC200_6_Sensor_4_R : 42.09
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 156.1
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 0
haITC502_5_Sensor_2_R : 89.19
haITC502_5_Sensor_3_R : 885.1
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.53
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -766
HacR_VPM_LVDT:VALr : 25
HacR_HPE1313A:0_Ch58 : -0.533691
HacR_HPE1313A:0_Ch55 : 22.3633
HacR_HPE1313A:0_Ch54 : -0.804688
HacR_alignROLL : -0.324102
HacR_alignPITCH : -0.021133
HacR_alignHPT : -1.96461
HacL_HPM_LVDT:VALr : -8059
HacL_VPM_LVDT:VALr : 1550
HacL_HPE1313A:0_Ch58 : -0.143066
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.237305
HacL_alignROLL : 0.123442
HacL_alignPITCH : -0.11695
HacL_alignHPT : 5.20915
Right Arm Angle Floor Angle : 24.5
Right Arm Angle Vernier : 52.6
Right Arm Scattering Angle : 25.0135
Left Arm Angle Floor Angle : 25
Left Arm Angle Vernier : 26.5
Left Arm Scattering Angle : 24.9385
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 110
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88