    User name adev

    Log entry time 01:10:36 on April 24, 2001

    Entry number 61191

    keyword=End_of_Run_3854
    ****************************
     Run Number: 3854
    End of Run Comment:
    RunType=Other,Tar=9foil-12C,Rad=out,comment=Junk,mode=singles,Lmom=0.9823,Rmom=0.450,Ene=3994,Angle_R=25,Angle_L=14.0
    
    
    Time of run = 4.1629068 min
    Av. current (on 3x) = 2.9674777 uA
    Av. current (on 1x) = 5.9461656 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    1.4852  |    0.7412  |    1.5022
    up-down    (mC)|   -0.0069  |    1.4937  |   -0.0072
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 894.59124 Hz  |    301465.2 /mC  |   89.459 Hz  |    223446  |    10   |    150448.4 /mC
        2      | 627.86256 Hz  |    211581.2 /mC  |   62.786 Hz  |    156824  |    10   |    105591.2 /mC
        3      | 697.01296 Hz  |    234884.0 /mC  |   23.234 Hz  |    174096  |    30   |    117220.6 /mC
        4      | 511.84587 Hz  |    172485.2 /mC  |    1.706 Hz  |    127846  |   300   |     86080.0 /mC
        5      | 10.261259 Hz  |      3457.9 /mC  |   10.261 Hz  |      2563  |     1   |      1725.7 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 0.080072 Hz  |        27.0 /mC  |    0.080 Hz  | 20.000024  |     1   |        13.5 /mC
        8    | 1024.0 Hz  |    345074.2 /mC  |    0.016 Hz  |    255769  | 65535   |    172211.8 /mC
        output                       175.150 Hz
    Av. deadtime from accepted triggers = 0.0588
    Av. deadtime from gated scalers = 0.0374
    Accepted triggers  =  43748.00000
    Rate of Left Arm Pulser for electronic DT  = 10.181187
    Rate of Right Arm Pulser for electronic DT  = 10.249249
    Rate of Left Arm Pulser&trig for electronic DT  = 10.181187
    Rate of Right Arm Pulser&trig for electronic DT  = 10.249249
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 9428.8522
    Rate of Right Arm Strobe  = 8118.7701
        Signal     |    Charge   (C)   
       upstream    |    0.0014818     
       upstream 3x |    0.0014881     
       upstream 10x|    0.0014986     
      downstream   |    0.0014887   
     downstream 3x |    -0.0000056   
     downstream 10x|    0.0015058    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 3854 at Tue Apr 24 01:10:25 EDT 2001
    Right Arm D1 momentum                    : 2.46261
    Right Arm arm angle                      : 25.0134
    Left Arm D1 momentum                      : 2.50001
    Left Arm arm angle                        : 24.9384
    Tiefenbach Hall A energy                : 4000.26
    Right Arm arm mispointing (HPT)          : -1.9602
    Left Arm arm mispointing (HPT)            : 5.21449
    Right Arm Q1 power supply current        : 1879.78
    Right Arm Q1 momentum                    : 2.49992
    Right Arm Q1 gauss meter                 : -0.04672
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1075.9
    Right Arm Q2 momentum                    : 2.5
    Right Arm Q2 gauss meter                 : 0.5653
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 944.226
    Right Arm D1 momentum                    : 2.46301
    Right Arm D1 NMR                         : 0.913995
    Right Arm Q3 power supply current        : 994.608
    Right Arm Q3 momentum                    : 2.49959
    Right Arm Q3 gauss meter                 : 0.4462
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1880.83
    Left Arm Q1 momentum                      : 2.5
    Left Arm Q1 gauss meter                   : -0.15902
    Left Arm Q1 power supply polarity         : 0
    Left Arm Q2 power supply current          : 1076.65
    Left Arm Q2 momentum                      : 2.50035
    Left Arm Q2 gauss meter                   : 0.5676
    Left Arm Q2 power supply polarity         : 1
    Left Arm D1 power supply current          : 861.224
    Left Arm D1 momentum                      : 2.50001
    Left Arm D1 NMR                           : 0.925312
    Left Arm Q3 power supply current          : 995.326
    Left Arm Q3 momentum                      : 2.50007
    Left Arm Q3 gauss meter                   : -0.4967
    Left Arm Q3 power supply polarity         : 1
    Average current of the two cavities     : 9.76702
    Current on Unser monitor                : 17.8893
    Current on Upstream bcm                 : 9.7537
    Current on Downstream bcm               : 9.78035
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 76.7824
    MBSY1c Hall A Beam energy               : 4007.96
    MBSY1c magnet current (amp)             : 167.034
    MBSY1c Bdl                              : 1.00019e+06
    MBSY3c Hall C Beam energy               : 2423.72
    Tiefenbach Hall A energy                : 4000.26
    Tiefenbach Hall C energy                : 2418.62
    Delta(E)/E width (MV_AI_DXWID)          : 3.69272
    IPM1C12.XPOS                            : 0.00450554
    IPM1H04A.XPOS                           : 1.66426
    IPM1H04A.YPOS                           : 0.812434
    IPM1H04B.XPOS                           : 1.02114
    IPM1H04B.YPOS                           : 0.181492
    Right Arm Arm Collimator                 : 0.61499
    Left Arm Arm Collimator                   : 0.617041
     HacR_HPM_LVDT:VALr                     : -771
     HacR_VPM_LVDT:VALr                     : 27
     HacR_HPE1313A:0_Ch58                   : -0.533691
     HacR_HPE1313A:0_Ch55                   : 22.5098
     HacR_HPE1313A:0_Ch54                   : -0.805176
     HacR_alignROLL                         : -0.323985
     HacR_alignPITCH                        : -0.0208172
     HacR_alignHPT                          : -1.95908
     HacL_HPM_LVDT:VALr                     : -8063
     HacL_VPM_LVDT:VALr                     : 1546
     HacL_HPE1313A:0_Ch58                   : -0.144043
     HacL_HPE1313A:0_Ch55                   : 23.7305
     HacL_HPE1313A:0_Ch54                   : -0.236328
     HacL_alignROLL                         : 0.124098
     HacL_alignPITCH                        : -0.116299
     HacL_alignHPT                          : 5.21666
    haBDSPOS                                 : 3.07567e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 59.5
    haL3_Fan_frequency_R                     : 37
    haH2_P_Fill_Target_R                     : 20.63
    haH2_P_Exhaust_R                         : 20.89
    haH2_P_Fill_Bottle_R                     : 20.7
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 18.75
    haD2_P_Fill_Bottle_R                     : 38.71
    haD2_DP_Fill_Exhaust_R                   : 0.0743
    haSC200_6_Sensor_1_R                     : 242.4
    haSC200_6_Sensor_2_R                     : 35.56
    haSC200_6_Sensor_3_R                     : 44.17
    haSC200_6_Sensor_4_R                     : 42.16
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.01
    haITC502_4_Sensor_1_R                    : 156.1
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22
    haITC502_5_Sensor_1_R                    : 88.51
    haITC502_5_Sensor_2_R                    : 26.7
    haITC502_5_Sensor_3_R                    : 2911.8
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 28.29
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.617041
    Wien angle                               : 32.9201
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 739.73
    Wien field                               : 21.203
    Laser attenuation Hall A                 : 119
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF