User name adev
Log entry time 04:10:54 on April 24, 2001
Entry number 61218
keyword=Start_Run_3855_RunType=Optics,Tar=9foil-12C,Rad=out,comment=Optics
Beginning-of-run EPICS data for Run Number 3855 at Tue Apr 24 01:54:33 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=10,ps2=10,ps3=30,ps4=300,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1879.81
Right Arm Q1 momentum : 2.49997
Right Arm Q1 gauss meter : -0.04672
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1075.76
Right Arm Q2 momentum : 2.49972
Right Arm Q2 gauss meter : 0.5653
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 882.142
Right Arm D1 momentum : 2.5
Right Arm D1 NMR : 0.92772
Right Arm Q3 power supply current : 994.598
Right Arm Q3 momentum : 2.49956
Right Arm Q3 gauss meter : 0.4462
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1880.83
Left Arm Q1 momentum : 2.5
Left Arm Q1 gauss meter : -0.15901
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1076.56
Left Arm Q2 momentum : 2.50013
Left Arm Q2 gauss meter : 0.5677
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 861.23
Left Arm D1 momentum : 2.50001
Left Arm D1 NMR : 0.92531
Left Arm Q3 power supply current : 995.283
Left Arm Q3 momentum : 2.49996
Left Arm Q3 gauss meter : -0.4966
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0590668
Current on Unser monitor : 6.39302
Current on Upstream bcm : 0.0621869
Current on Downstream bcm : 0.0559467
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 66.0491
Beam energy : 4007.96
MBSY1c magnet current (amp) : 167.034
Radiator 5V Linear Supply : 5.02076
Radiator Encoder : 0.163614
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 73.5
haL3_Fan_frequency_R : 37
haSC200_6_Sensor_1_R : 241.91
haSC200_6_Sensor_2_R : 35.33
haSC200_6_Sensor_3_R : 43.94
haSC200_6_Sensor_4_R : 41.96
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 156.3
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 89.17
haITC502_5_Sensor_2_R : 291.09
haITC502_5_Sensor_3_R : 268.5
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.34
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -745
HacR_VPM_LVDT:VALr : -7
HacR_HPE1313A:0_Ch58 : -0.537109
HacR_HPE1313A:0_Ch55 : 22.3145
HacR_HPE1313A:0_Ch54 : -0.808105
HacR_alignROLL : -0.327552
HacR_alignPITCH : -0.0188889
HacR_alignHPT : -1.99622
HacL_HPM_LVDT:VALr : -8065
HacL_VPM_LVDT:VALr : 1552
HacL_HPE1313A:0_Ch58 : -0.143066
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : -0.231934
HacL_alignROLL : 0.127787
HacL_alignPITCH : -0.116876
HacL_alignHPT : 5.21712
Right Arm Angle Floor Angle : 24.5
Right Arm Angle Vernier : 52.6
Right Arm Scattering Angle : 25.0137
Left Arm Angle Floor Angle : 25
Left Arm Angle Vernier : 26.5
Left Arm Scattering Angle : 24.9384
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 225
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88