User name adev
Log entry time 12:26:27 on April 24, 2001
Entry number 61245
keyword=Start_Run_3870_RunType=Elastic,Tar=LH2-15cm,Rad=out,comment=dvcs
Beginning-of-run EPICS data for Run Number 3870 at Tue Apr 24 12:16:27 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=4,ps2=4,ps3=65535,ps4=65535,ps5=4,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 2330.93
Right Arm Q1 momentum : 3.09991
Right Arm Q1 gauss meter : -0.0579
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1334.27
Right Arm Q2 momentum : 3.10032
Right Arm Q2 gauss meter : 0.7003
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1117.15
Right Arm D1 momentum : 3.1
Right Arm D1 NMR : 1.15037
Right Arm Q3 power supply current : 1233.56
Right Arm Q3 momentum : 3.1001
Right Arm Q3 gauss meter : 0.553
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 752.115
Left Arm Q1 momentum : 0.999712
Left Arm Q1 gauss meter : -0.06366
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 430.708
Left Arm Q2 momentum : 1.00025
Left Arm Q2 gauss meter : 0.2276
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 333.479
Left Arm D1 momentum : 0.999993
Left Arm D1 NMR : 0.370228
Left Arm Q3 power supply current : 398.132
Left Arm Q3 momentum : 1.00003
Left Arm Q3 gauss meter : -0.19865
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.960543
Current on Unser monitor : 9.00972
Current on Upstream bcm : 0.954376
Current on Downstream bcm : 0.955543
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 68.4001
Beam energy : 4007.96
MBSY1c magnet current (amp) : 167.034
Radiator 5V Linear Supply : 5.0232
Radiator Encoder : 0.161172
haBDSPOS : 5.3284e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 65
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 242.71
haSC200_6_Sensor_2_R : 35.9
haSC200_6_Sensor_3_R : 44.37
haSC200_6_Sensor_4_R : 42.32
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 158.3
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 0
haITC502_5_Sensor_2_R : 290.55
haITC502_5_Sensor_3_R : 0
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.17
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -3648
HacR_VPM_LVDT:VALr : 422
HacR_HPE1313A:0_Ch58 : -0.524902
HacR_HPE1313A:0_Ch55 : 22.5098
HacR_HPE1313A:0_Ch54 : -0.837891
HacR_alignROLL : -0.357997
HacR_alignPITCH : -0.0293452
HacR_alignHPT : 1.30615
HacL_HPM_LVDT:VALr : -8524
HacL_VPM_LVDT:VALr : 746
HacL_HPE1313A:0_Ch58 : -0.32959
HacL_HPE1313A:0_Ch55 : 23.9258
HacL_HPE1313A:0_Ch54 : -0.253906
HacL_alignROLL : 0.108407
HacL_alignPITCH : 0.0498557
HacL_alignHPT : 5.74041
Right Arm Angle Floor Angle : 21
Right Arm Angle Vernier : 52.6
Right Arm Scattering Angle : 21.4913
Left Arm Angle Floor Angle : 25
Left Arm Angle Vernier : 26.5
Left Arm Scattering Angle : 24.9349
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 115
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88