Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 14:52:13 on April 24, 2001
Entry number 61258
keyword=Start_Run_3877_RunType=Elastic,Tar=LH2-15cm,Rad=out,comment=dvcs
Beginning-of-run EPICS data for Run Number 3877 at Tue Apr 24 14:52:04 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=4,ps2=4,ps3=65535,ps4=65535,ps5=4,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1879.89
Right Arm Q1 momentum : 2.50006
Right Arm Q1 gauss meter : -0.04676
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1076.09
Right Arm Q2 momentum : 2.5004
Right Arm Q2 gauss meter : 0.5652
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 959.502
Right Arm D1 momentum : 2.79425
Right Arm D1 NMR : 1.03691
Right Arm Q3 power supply current : 994.819
Right Arm Q3 momentum : 2.50012
Right Arm Q3 gauss meter : 0.4461
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 752.115
Left Arm Q1 momentum : 0.999712
Left Arm Q1 gauss meter : -0.06367
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 430.401
Left Arm Q2 momentum : 0.999538
Left Arm Q2 gauss meter : 0.2275
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 333.475
Left Arm D1 momentum : 0.999992
Left Arm D1 NMR : 0.370228
Left Arm Q3 power supply current : 398.183
Left Arm Q3 momentum : 1.00016
Left Arm Q3 gauss meter : -0.19866
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.585751
Current on Unser monitor : 8.55864
Current on Upstream bcm : 0.579577
Current on Downstream bcm : 0.591926
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 0.534444
Beam energy : 4007.96
MBSY1c magnet current (amp) : 167.034
Radiator 5V Linear Supply : 5.0232
Radiator Encoder : 0.151404
haBDSPOS : 5.3284e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 242.65
haSC200_6_Sensor_2_R : 35.77
haSC200_6_Sensor_3_R : 44.35
haSC200_6_Sensor_4_R : 42.22
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 158.7
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 0.06
haITC502_5_Sensor_2_R : 289.27
haITC502_5_Sensor_3_R : 0
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.16
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -3636
HacR_VPM_LVDT:VALr : 398
HacR_HPE1313A:0_Ch58 : -0.525879
HacR_HPE1313A:0_Ch55 : 22.4609
HacR_HPE1313A:0_Ch54 : -0.838379
HacR_alignROLL : -0.35794
HacR_alignPITCH : -0.0289631
HacR_alignHPT : 1.29268
HacL_HPM_LVDT:VALr : -8526
HacL_VPM_LVDT:VALr : 748
HacL_HPE1313A:0_Ch58 : -0.328125
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : -0.252441
HacL_alignROLL : 0.110103
HacL_alignPITCH : 0.0477426
HacL_alignHPT : 5.74071
Right Arm Angle Floor Angle : 21
Right Arm Angle Vernier : 52.6
Right Arm Scattering Angle : 21.4914
Left Arm Angle Floor Angle : 25
Left Arm Angle Vernier : 26.5
Left Arm Scattering Angle : 24.9349
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 95
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88