User name adev
Log entry time 17:56:23 on April 24, 2001
Entry number 61267
keyword=Start_Run_3880_RunType=Elastic,Tar=LH2-15cm,Rad=out,comment=collimators
Beginning-of-run EPICS data for Run Number 3880 at Tue Apr 24 17:56:10 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=16,ps2=1,ps3=16,ps4=1,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 800.695
Right Arm Q1 momentum : 1.06485
Right Arm Q1 gauss meter : -0.02
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 458.271
Right Arm Q2 momentum : 1.06484
Right Arm Q2 gauss meter : 0.2409
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 364.937
Right Arm D1 momentum : 1.06503
Right Arm D1 NMR : 0.395218
Right Arm Q3 power supply current : 423.988
Right Arm Q3 momentum : 1.06554
Right Arm Q3 gauss meter : 0.1899
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 800.87
Left Arm Q1 momentum : 1.06452
Left Arm Q1 gauss meter : -0.06777
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 458.562
Left Arm Q2 momentum : 1.06494
Left Arm Q2 gauss meter : 0.2423
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 355.281
Left Arm D1 momentum : 1.065
Left Arm D1 NMR : 0.394278
Left Arm Q3 power supply current : 424.068
Left Arm Q3 momentum : 1.06518
Left Arm Q3 gauss meter : -0.2114
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 85.9688
Current on Unser monitor : 94.4792
Current on Upstream bcm : 85.8747
Current on Downstream bcm : 86.063
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 154.089
Beam energy : 4007.96
MBSY1c magnet current (amp) : 167.034
Radiator 5V Linear Supply : 5.02564
Radiator Encoder : 0.163614
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 66.5
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 242.16
haSC200_6_Sensor_2_R : 35.7
haSC200_6_Sensor_3_R : 44.22
haSC200_6_Sensor_4_R : 42.24
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 159
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 88.42
haITC502_5_Sensor_2_R : 87.74
haITC502_5_Sensor_3_R : 264.8
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.19
Right Arm Arm Collimator : 0.865234
Left Arm Arm Collimator : 0.868799
HacR_HPM_LVDT:VALr : -4801
HacR_VPM_LVDT:VALr : 598
HacR_HPE1313A:0_Ch58 : -0.532227
HacR_HPE1313A:0_Ch55 : 22.3633
HacR_HPE1313A:0_Ch54 : -0.89502
HacR_alignROLL : -0.415233
HacR_alignPITCH : -0.022546
HacR_alignHPT : 2.55104
HacL_HPM_LVDT:VALr : -6624
HacL_VPM_LVDT:VALr : -466
HacL_HPE1313A:0_Ch58 : -0.265137
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.273926
HacL_alignROLL : 0.0894269
HacL_alignPITCH : -0.00779428
HacL_alignHPT : 3.62543
Right Arm Angle Floor Angle : 45
Right Arm Angle Vernier : -35.1
Right Arm Scattering Angle : 44.9774
Left Arm Angle Floor Angle : 45
Left Arm Angle Vernier : 31.5
Left Arm Scattering Angle : 44.978
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 367
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88