User name adev
Log entry time 19:01:45 on April 24, 2001
Entry number 61269
keyword=Start_Run_3881_RunType=Elastic,Tar=LH2-15cm,Rad=out,comment=collimators
Beginning-of-run EPICS data for Run Number 3881 at Tue Apr 24 19:01:34 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=16,ps2=1,ps3=16,ps4=1,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 800.765
Right Arm Q1 momentum : 1.06494
Right Arm Q1 gauss meter : -0.02
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 458.16
Right Arm Q2 momentum : 1.06458
Right Arm Q2 gauss meter : 0.241
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 363.438
Right Arm D1 momentum : 1.065
Right Arm D1 NMR : 0.395209
Right Arm Q3 power supply current : 423.564
Right Arm Q3 momentum : 1.06448
Right Arm Q3 gauss meter : 0.18989
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 800.87
Left Arm Q1 momentum : 1.06452
Left Arm Q1 gauss meter : -0.06774
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 458.526
Left Arm Q2 momentum : 1.06485
Left Arm Q2 gauss meter : 0.2423
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 355.282
Left Arm D1 momentum : 1.065
Left Arm D1 NMR : 0.394278
Left Arm Q3 power supply current : 423.996
Left Arm Q3 momentum : 1.065
Left Arm Q3 gauss meter : -0.2114
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 86.6202
Current on Unser monitor : 92.506
Current on Upstream bcm : 85.8977
Current on Downstream bcm : 86.0996
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 154.293
Beam energy : 4007.96
MBSY1c magnet current (amp) : 167.034
Radiator 5V Linear Supply : 5.02564
Radiator Encoder : 0.161172
haBDSPOS : 4.6174e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 67.5
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 242
haSC200_6_Sensor_2_R : 35.63
haSC200_6_Sensor_3_R : 44.12
haSC200_6_Sensor_4_R : 42.14
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 159.1
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 288.15
haITC502_5_Sensor_2_R : 0
haITC502_5_Sensor_3_R : 0
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.2
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4830
HacR_VPM_LVDT:VALr : 606
HacR_HPE1313A:0_Ch58 : -0.530273
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.898926
HacR_alignROLL : -0.419177
HacR_alignPITCH : -0.0243413
HacR_alignHPT : 2.58656
HacL_HPM_LVDT:VALr : -6615
HacL_VPM_LVDT:VALr : -433
HacL_HPE1313A:0_Ch58 : -0.262207
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.277832
HacL_alignROLL : 0.0863346
HacL_alignPITCH : -0.010414
HacL_alignHPT : 3.61574
Right Arm Angle Floor Angle : 45
Right Arm Angle Vernier : -35.1
Right Arm Scattering Angle : 44.9772
Left Arm Angle Floor Angle : 45
Left Arm Angle Vernier : 31.5
Left Arm Scattering Angle : 44.9781
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 358
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88