• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 20:28:34 on April 24, 2001

    Entry number 61276

    keyword=End_of_Run_3883
    ****************************
     Run Number: 3883
    End of Run Comment:
    RunType=Elastic,Tar=LH2-15cm,Rad=out,comment=collimators open,mode=singles,Lmom=1.0437,Rmom=1.0437,Ene=3994,Angle_R=44.97,Angle_L=44.978
    
    Time of run = 19.069238 min
    Av. current (on 3x) = 43.289703 uA
    Av. current (on 1x) = 86.556158 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   99.0336  |   49.5301  |   87.1179
    up-down    (mC)|   -0.9384  |   99.1119  |   -2.1928
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 9390.1094 Hz  |    216913.2 /mC  |  586.882 Hz  |  10743734  |    16   |    108485.8 /mC
        2      | 583.90464 Hz  |     13488.3 /mC  |  583.905 Hz  |    668077  |     1   |      6746.0 /mC
        3      | 9482.4518 Hz  |    219046.4 /mC  |  592.653 Hz  |  10849388  |    16   |    109552.6 /mC
        4      | 687.29891 Hz  |     15876.7 /mC  |  687.299 Hz  |    786376  |     1   |      7940.5 /mC
        5      | 18.290365 Hz  |       422.5 /mC  |   18.290 Hz  |     20927  |     1   |       211.3 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 8.119534 Hz  |       187.6 /mC  |    8.120 Hz  | 9290.0  |     1   |        93.8 /mC
        8    | 1024.0 Hz  |     23654.6 /mC  |    0.016 Hz  |   1171614  | 65535   |     11830.5 /mC
        output                      1764.632 Hz
    Av. deadtime from accepted triggers = 0.2846
    Av. deadtime from gated scalers = 0.2764
    Accepted triggers  = 2019011.00000
    Rate of Left Arm Pulser for electronic DT  = 10.170831
    Rate of Right Arm Pulser for electronic DT  = 10.232886
    Rate of Left Arm Pulser&trig for electronic DT  = 10.168209
    Rate of Right Arm Pulser&trig for electronic DT  = 10.232012
    Left Arm Electronic DT  = 0.0002577984
    Right Arm Electronic DT  = 8.5411684e-05
    Rate of Left Strobe  = 59398.039
    Rate of Right Arm Strobe  = 48736.498
        Signal     |    Charge   (C)   
       upstream    |    0.0985644     
       upstream 3x |    0.0990861     
       upstream 10x|    0.0860215     
      downstream   |    0.0995028   
     downstream 3x |    -0.0000258   
     downstream 10x|    0.0882143    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 3883 at Tue Apr 24 20:28:19 EDT 2001
    Right Arm D1 momentum                    : 1.0437
    Right Arm arm angle                      : 44.9773
    Left Arm D1 momentum                      : 1.04369
    Left Arm arm angle                        : 44.9781
    Tiefenbach Hall A energy                : 0
    Right Arm arm mispointing (HPT)          : 2.5727
    Left Arm arm mispointing (HPT)            : 3.61362
    Right Arm Q1 power supply current        : 784.735
    Right Arm Q1 momentum                    : 1.04362
    Right Arm Q1 gauss meter                 : -0.01964
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 449.37
    Right Arm Q2 momentum                    : 1.04416
    Right Arm Q2 gauss meter                 : 0.2362
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 356.032
    Right Arm D1 momentum                    : 1.0437
    Right Arm D1 NMR                         : 0.387305
    Right Arm Q3 power supply current        : 415.568
    Right Arm Q3 momentum                    : 1.04438
    Right Arm Q3 gauss meter                 : 0.18615
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 784.84
    Left Arm Q1 momentum                      : 1.04321
    Left Arm Q1 gauss meter                   : -0.06642
    Left Arm Q1 power supply polarity         : 0
    Left Arm Q2 power supply current          : 449.195
    Left Arm Q2 momentum                      : 1.04325
    Left Arm Q2 gauss meter                   : 0.2374
    Left Arm Q2 power supply polarity         : 1
    Left Arm D1 power supply current          : 348.048
    Left Arm D1 momentum                      : 1.04369
    Left Arm D1 NMR                           : 0.386396
    Left Arm Q3 power supply current          : 415.542
    Left Arm Q3 momentum                      : 1.04377
    Left Arm Q3 gauss meter                   : -0.207
    Left Arm Q3 power supply polarity         : 1
    Average current of the two cavities     : 87.2096
    Current on Unser monitor                : 94.115
    Current on Upstream bcm                 : 87.221
    Current on Downstream bcm               : 87.1982
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 155.832
    MBSY1c Hall A Beam energy               : 4007.96
    MBSY1c magnet current (amp)             : 167.034
    MBSY1c Bdl                              : 1.00019e+06
    MBSY3c Hall C Beam energy               : 2424.72
    Tiefenbach Hall A energy                : 0
    Tiefenbach Hall C energy                : 0
    Delta(E)/E width (MV_AI_DXWID)          : 3.71397
    IPM1C12.XPOS                            : 0.00173998
    IPM1H04A.XPOS                           : 1.6561
    IPM1H04A.YPOS                           : 0.644902
    IPM1H04B.XPOS                           : 0.999683
    IPM1H04B.YPOS                           : -0.0362941
    Right Arm Arm Collimator                 : 0.865332
    Left Arm Arm Collimator                   : 0.868506
     HacR_HPM_LVDT:VALr                     : -4817
     HacR_VPM_LVDT:VALr                     : 624
     HacR_HPE1313A:0_Ch58                   : -0.527832
     HacR_HPE1313A:0_Ch55                   : 22.4609
     HacR_HPE1313A:0_Ch54                   : -0.902344
     HacR_alignROLL                         : -0.422134
     HacR_alignPITCH                        : -0.0256878
     HacR_alignHPT                          : 2.5727
     HacL_HPM_LVDT:VALr                     : -6613
     HacL_VPM_LVDT:VALr                     : -435
     HacL_HPE1313A:0_Ch58                   : -0.260742
     HacL_HPE1313A:0_Ch55                   : 23.7305
     HacL_HPE1313A:0_Ch54                   : -0.279297
     HacL_alignROLL                         : 0.0847087
     HacL_alignPITCH                        : -0.0114304
     HacL_alignHPT                          : 3.61317
    haBDSPOS                                 : 4.6174e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 66.5
    haL3_Fan_frequency_R                     : 25
    haH2_P_Fill_Target_R                     : 20.95
    haH2_P_Exhaust_R                         : 21.23
    haH2_P_Fill_Bottle_R                     : 21.04
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 19.2
    haD2_P_Fill_Bottle_R                     : 39.64
    haD2_DP_Fill_Exhaust_R                   : 0.0742
    haSC200_6_Sensor_1_R                     : 242.38
    haSC200_6_Sensor_2_R                     : 35.75
    haSC200_6_Sensor_3_R                     : 44.3
    haSC200_6_Sensor_4_R                     : 42.29
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.25
    haITC502_4_Sensor_1_R                    : 159.3
    haITC502_4_Sensor_2_R                    : 19.2
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 0
    haITC502_5_Sensor_2_R                    : 0
    haITC502_5_Sensor_3_R                    : 39.9
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 28.21
    Right Arm Arm Collimator                 : 0.865381
    Left Arm Arm Collimator                   : 0.868457
    Wien angle                               : 
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 739.73
    Wien field                               : 21.203
    Laser attenuation Hall A                 : 369
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF