User name adev
Log entry time 21:05:35 on April 24, 2001
Entry number 61279
keyword=Start_Run_3885_RunType=Elastic,Tar=9foil-12C,Rad=out,comment=collimators
Beginning-of-run EPICS data for Run Number 3885 at Tue Apr 24 21:05:25 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=16,ps2=1,ps3=16,ps4=1,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 768.985
Right Arm Q1 momentum : 1.02268
Right Arm Q1 gauss meter : -0.019259
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 440.394
Right Arm Q2 momentum : 1.0233
Right Arm Q2 gauss meter : 0.2315
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 348.854
Right Arm D1 momentum : 1.0228
Right Arm D1 NMR : 0.379549
Right Arm Q3 power supply current : 406.973
Right Arm Q3 momentum : 1.02278
Right Arm Q3 gauss meter : 0.18241
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 769.23
Left Arm Q1 momentum : 1.02246
Left Arm Q1 gauss meter : -0.06508
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 440.164
Left Arm Q2 momentum : 1.02221
Left Arm Q2 gauss meter : 0.2328
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 340.95
Left Arm D1 momentum : 1.0228
Left Arm D1 NMR : 0.378664
Left Arm Q3 power supply current : 407.212
Left Arm Q3 momentum : 1.02284
Left Arm Q3 gauss meter : -0.2029
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 80.4679
Current on Unser monitor : 90.0948
Current on Upstream bcm : 80.592
Current on Downstream bcm : 82.7923
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 146.244
Beam energy : 4007.96
MBSY1c magnet current (amp) : 167.034
Radiator 5V Linear Supply : 5.02076
Radiator Encoder : 0.163614
haBDSPOS : 2.47884e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 64.5
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 242.3
haSC200_6_Sensor_2_R : 35.7
haSC200_6_Sensor_3_R : 44.29
haSC200_6_Sensor_4_R : 42.21
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 159.3
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 0.06
haITC502_5_Sensor_2_R : 287.98
haITC502_5_Sensor_3_R : 0
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.13
Right Arm Arm Collimator : 0.865381
Left Arm Arm Collimator : 0.868506
HacR_HPM_LVDT:VALr : -4814
HacR_VPM_LVDT:VALr : 606
HacR_HPE1313A:0_Ch58 : -0.528809
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.903809
HacR_alignROLL : -0.424543
HacR_alignPITCH : -0.0262034
HacR_alignHPT : 2.57075
HacL_HPM_LVDT:VALr : -6598
HacL_VPM_LVDT:VALr : -427
HacL_HPE1313A:0_Ch58 : -0.260254
HacL_HPE1313A:0_Ch55 : 23.6816
HacL_HPE1313A:0_Ch54 : -0.282715
HacL_alignROLL : 0.0819876
HacL_alignPITCH : -0.0117955
HacL_alignHPT : 3.59995
Right Arm Angle Floor Angle : 45
Right Arm Angle Vernier : -35.1
Right Arm Scattering Angle : 44.9773
Left Arm Angle Floor Angle : 45
Left Arm Angle Vernier : 31.5
Left Arm Scattering Angle : 44.9782
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 352
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88