Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 08:07:47 on April 25, 2001
Entry number 61314
keyword=Start_Run_3899_RunType=Other,Tar=9foil-12C,Rad=out,comment=Harp
Beginning-of-run EPICS data for Run Number 3899 at Wed Apr 25 08:07:35 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=30,ps2=400,ps3=30,ps4=400,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 627.2
Right Arm Q1 momentum : 0.834115
Right Arm Q1 gauss meter : -0.015712
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 358.815
Right Arm Q2 momentum : 0.833741
Right Arm Q2 gauss meter : 0.18878
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 284.375
Right Arm D1 momentum : 0.834001
Right Arm D1 NMR : 0.309488
Right Arm Q3 power supply current : 331.674
Right Arm Q3 momentum : 0.833542
Right Arm Q3 gauss meter : 0.14876
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 627.305
Left Arm Q1 momentum : 0.833815
Left Arm Q1 gauss meter : -0.05311
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 359.132
Left Arm Q2 momentum : 0.834026
Left Arm Q2 gauss meter : 0.18988
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 277.703
Left Arm D1 momentum : 0.833986
Left Arm D1 NMR : 0.308809
Left Arm Q3 power supply current : 332.085
Left Arm Q3 momentum : 0.834137
Left Arm Q3 gauss meter : -0.16547
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 5.6394
Current on Unser monitor : 12.8475
Current on Upstream bcm : 5.63
Current on Downstream bcm : 5.64879
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 69.0418
Beam energy : 835.372
MBSY1c magnet current (amp) : 34.4338
Radiator 5V Linear Supply : 5.0232
Radiator Encoder : 0.161172
haBDSPOS : 2.47884e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62.5
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 242.08
haSC200_6_Sensor_2_R : 35.68
haSC200_6_Sensor_3_R : 44.22
haSC200_6_Sensor_4_R : 42.21
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 159.9
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 0
haITC502_5_Sensor_2_R : 0
haITC502_5_Sensor_3_R : 39.9
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.14
Right Arm Arm Collimator : 0.363965
Left Arm Arm Collimator : 0.366016
HacR_HPM_LVDT:VALr : -1001
HacR_VPM_LVDT:VALr : -665
HacR_HPE1313A:0_Ch58 : -0.539062
HacR_HPE1313A:0_Ch55 : 22.3145
HacR_HPE1313A:0_Ch54 : -0.824707
HacR_alignROLL : -0.344427
HacR_alignPITCH : -0.0160631
HacR_alignHPT : -1.66569
HacL_HPM_LVDT:VALr : -6962
HacL_VPM_LVDT:VALr : 1842
HacL_HPE1313A:0_Ch58 : -0.184082
HacL_HPE1313A:0_Ch55 : 23.6328
HacL_HPE1313A:0_Ch54 : -0.0117188
HacL_alignROLL : 0.33047
HacL_alignPITCH : -0.100824
HacL_alignHPT : 3.88963
Right Arm Angle Floor Angle : 15
Right Arm Angle Vernier : -34.1
Right Arm Scattering Angle : 15.0117
Left Arm Angle Floor Angle : 15
Left Arm Angle Vernier : 30.8
Left Arm Scattering Angle : 14.9722
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 195
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88