    User name adev

    Log entry time 08:09:53 on April 25, 2001

    Entry number 61316

    keyword=End_of_Run_3899
    ****************************
     Run Number: 3899
    End of Run Comment:
    RunType=Other,Tar=9foil-12C,Rad=out,comment=Harp scan,mode=singles,Lmom=0.834,Rmom=0.834,Ene=834.4,Angle_R=15.0,Angle_L=15.0
    
    
    Time of run = 1.9163248 min
    Av. current (on 3x) = 2.8613799 uA
    Av. current (on 1x) = 5.7340661 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    0.6593  |    0.3290  |    0.6669
    up-down    (mC)|   -0.0025  |    0.6631  |   -0.0033
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 1878.4307 Hz  |    656477.2 /mC  |   62.614 Hz  |    215981  |    30   |    327591.4 /mC
        2      | 1819.7158 Hz  |    635957.4 /mC  |    4.549 Hz  |    209230  |   400   |    317351.7 /mC
        3      | 2429.8942 Hz  |    849203.7 /mC  |   80.996 Hz  |    279388  |    30   |    423764.6 /mC
        4      | 2364.4652 Hz  |    826337.4 /mC  |    5.911 Hz  |    271865  |   400   |    412354.0 /mC
        5      | 10.810624 Hz  |      3778.1 /mC  |   10.811 Hz  |      1243  |     1   |      1885.3 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 0.617502 Hz  |       215.8 /mC  |    0.618 Hz  | 71.000031  |     1   |       107.7 /mC
        8    | 1024.0 Hz  |    357869.3 /mC  |    0.016 Hz  |    117739  | 65535   |    178581.8 /mC
        output                       160.942 Hz
    Av. deadtime from accepted triggers = 0.0197
    Av. deadtime from gated scalers = 0.0221
    Accepted triggers  =  18505.00000
    Rate of Left Arm Pulser for electronic DT  = 10.193122
    Rate of Right Arm Pulser for electronic DT  = 10.436644
    Rate of Left Arm Pulser&trig for electronic DT  = 10.193122
    Rate of Right Arm Pulser&trig for electronic DT  = 10.436644
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 6759.1098
    Rate of Right Arm Strobe  = 5722.5945
        Signal     |    Charge   (C)   
       upstream    |    0.0006580     
       upstream 3x |    0.0006605     
       upstream 10x|    0.0006652     
      downstream   |    0.0006605   
     downstream 3x |    -0.0000026   
     downstream 10x|    0.0006685    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 3899 at Wed Apr 25 08:09:44 EDT 2001
    Right Arm D1 momentum                    : 0.834002
    Right Arm arm angle                      : 15.0117
    Left Arm D1 momentum                      : 0.833988
    Left Arm arm angle                        : 14.9722
    Tiefenbach Hall A energy                : 0
    Right Arm arm mispointing (HPT)          : -1.66544
    Left Arm arm mispointing (HPT)            : 3.88736
    Right Arm Q1 power supply current        : 627.2
    Right Arm Q1 momentum                    : 0.834115
    Right Arm Q1 gauss meter                 : -0.01572
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 358.946
    Right Arm Q2 momentum                    : 0.834045
    Right Arm Q2 gauss meter                 : 0.18886
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 284.383
    Right Arm D1 momentum                    : 0.834002
    Right Arm D1 NMR                         : 0.309488
    Right Arm Q3 power supply current        : 331.994
    Right Arm Q3 momentum                    : 0.834348
    Right Arm Q3 gauss meter                 : 0.1488
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 627.305
    Left Arm Q1 momentum                      : 0.833815
    Left Arm Q1 gauss meter                   : -0.05311
    Left Arm Q1 power supply polarity         : 0
    Left Arm Q2 power supply current          : 359.091
    Left Arm Q2 momentum                      : 0.833932
    Left Arm Q2 gauss meter                   : 0.18982
    Left Arm Q2 power supply polarity         : 1
    Left Arm D1 power supply current          : 277.704
    Left Arm D1 momentum                      : 0.833987
    Left Arm D1 NMR                           : 0.308809
    Left Arm Q3 power supply current          : 332.034
    Left Arm Q3 momentum                      : 0.834008
    Left Arm Q3 gauss meter                   : -0.16547
    Left Arm Q3 power supply polarity         : 1
    Average current of the two cavities     : 5.89392
    Current on Unser monitor                : 14.4285
    Current on Upstream bcm                 : 5.86837
    Current on Downstream bcm               : 5.82625
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 69.0338
    MBSY1c Hall A Beam energy               : 835.372
    MBSY1c magnet current (amp)             : 34.4338
    MBSY1c Bdl                              : 208468
    MBSY3c Hall C Beam energy               : 2424.72
    Tiefenbach Hall A energy                : 0
    Tiefenbach Hall C energy                : 0
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : 0.440935
    IPM1H04A.XPOS                           : -0.340526
    IPM1H04A.YPOS                           : 0.33995
    IPM1H04B.XPOS                           : -0.256501
    IPM1H04B.YPOS                           : -1.03456
    Right Arm Arm Collimator                 : 0.363867
    Left Arm Arm Collimator                   : 0.366064
     HacR_HPM_LVDT:VALr                     : -1000
     HacR_VPM_LVDT:VALr                     : -663
     HacR_HPE1313A:0_Ch58                   : -0.539062
     HacR_HPE1313A:0_Ch55                   : 22.3145
     HacR_HPE1313A:0_Ch54                   : -0.82373
     HacR_alignROLL                         : -0.343383
     HacR_alignPITCH                        : -0.0161295
     HacR_alignHPT                          : -1.66628
     HacL_HPM_LVDT:VALr                     : -6966
     HacL_VPM_LVDT:VALr                     : 1840
     HacL_HPE1313A:0_Ch58                   : -0.183105
     HacL_HPE1313A:0_Ch55                   : 23.6328
     HacL_HPE1313A:0_Ch54                   : -0.0126953
     HacL_alignROLL                         : 0.329617
     HacL_alignPITCH                        : -0.101771
     HacL_alignHPT                          : 3.89227
    haBDSPOS                                 : 2.47884e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 64
    haL3_Fan_frequency_R                     : 24.5
    haH2_P_Fill_Target_R                     : 20.09
    haH2_P_Exhaust_R                         : 20.4
    haH2_P_Fill_Bottle_R                     : 20.14
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 18.34
    haD2_P_Fill_Bottle_R                     : 37.91
    haD2_DP_Fill_Exhaust_R                   : 0.0742
    haSC200_6_Sensor_1_R                     : 242.05
    haSC200_6_Sensor_2_R                     : 35.67
    haSC200_6_Sensor_3_R                     : 44.19
    haSC200_6_Sensor_4_R                     : 42.19
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.02
    haITC502_4_Sensor_1_R                    : 159.9
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 26.7
    haITC502_5_Sensor_2_R                    : 288.82
    haITC502_5_Sensor_3_R                    : 0
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 28.14
    Right Arm Arm Collimator                 : 0.363867
    Left Arm Arm Collimator                   : 0.366064
    Wien angle                               : 32.9201
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 739.73
    Wien field                               : 21.203
    Laser attenuation Hall A                 : 195
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF