    User name adev

    Log entry time 08:25:14 on April 25, 2001

    Entry number 61320

    keyword=End_of_Run_3901
    ****************************
     Run Number: 3901
    End of Run Comment:
    RunType=Other,Tar=9foil-12C,Rad=out,comment=,mode=singles,Lmom=0.834,Rmom=0.834,Ene=834.4,Angle_R=15.0,Angle_L=15.0
    
    Time of run = 2.342985 min
    Av. current (on 3x) = 2.4840108 uA
    Av. current (on 1x) = 4.9808257 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    0.7002  |    0.3492  |    0.7089
    up-down    (mC)|   -0.0020  |    0.7048  |   -0.0035
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 3071.2958 Hz  |   1236426.1 /mC  | 1023.765 Hz  |    431760  |     3   |    616623.8 /mC
        2      | 2992.9342 Hz  |   1204879.7 /mC  |    7.482 Hz  |    420744  |   400   |    600891.2 /mC
        3      | 3453.2445 Hz  |   1390189.0 /mC  | 1151.082 Hz  |    485454  |     3   |    693307.6 /mC
        4      | 3366.3895 Hz  |   1355223.4 /mC  |    8.416 Hz  |    473244  |   400   |    675869.8 /mC
        5      | 11.345926 Hz  |      4567.6 /mC  |   11.346 Hz  |      1595  |     1   |      2277.9 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 1.166603 Hz  |       469.6 /mC  |    1.167 Hz  | 163.99993  |     1   |       234.2 /mC
        8    | 1024.0 Hz  |    412236.5 /mC  |    0.016 Hz  |    143953  | 65535   |    205588.4 /mC
        output                       572.973 Hz
    Av. deadtime from accepted triggers = 0.7389
    Av. deadtime from gated scalers = 0.7692
    Accepted triggers  =  80548.00000
    Rate of Left Arm Pulser for electronic DT  = 10.179323
    Rate of Right Arm Pulser for electronic DT  = 10.307364
    Rate of Left Arm Pulser&trig for electronic DT  = 10.179323
    Rate of Right Arm Pulser&trig for electronic DT  = 10.307364
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 9095.4843
    Rate of Right Arm Strobe  = 7953.6645
        Signal     |    Charge   (C)   
       upstream    |    0.0006992     
       upstream 3x |    0.0007016     
       upstream 10x|    0.0007072     
      downstream   |    0.0007012   
     downstream 3x |    -0.0000032   
     downstream 10x|    0.0007107    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 3901 at Wed Apr 25 08:25:04 EDT 2001
    Right Arm D1 momentum                    : 0.834
    Right Arm arm angle                      : 15.0118
    Left Arm D1 momentum                      : 0.83399
    Left Arm arm angle                        : 14.9722
    Tiefenbach Hall A energy                : 0
    Right Arm arm mispointing (HPT)          : -1.67209
    Left Arm arm mispointing (HPT)            : 3.89193
    Right Arm Q1 power supply current        : 627.2
    Right Arm Q1 momentum                    : 0.834115
    Right Arm Q1 gauss meter                 : -0.015728
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 358.891
    Right Arm Q2 momentum                    : 0.833919
    Right Arm Q2 gauss meter                 : 0.18883
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 284.376
    Right Arm D1 momentum                    : 0.834
    Right Arm D1 NMR                         : 0.309487
    Right Arm Q3 power supply current        : 331.794
    Right Arm Q3 momentum                    : 0.833845
    Right Arm Q3 gauss meter                 : 0.14875
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 627.305
    Left Arm Q1 momentum                      : 0.833815
    Left Arm Q1 gauss meter                   : -0.05313
    Left Arm Q1 power supply polarity         : 0
    Left Arm Q2 power supply current          : 358.931
    Left Arm Q2 momentum                      : 0.83356
    Left Arm Q2 gauss meter                   : 0.18986
    Left Arm Q2 power supply polarity         : 1
    Left Arm D1 power supply current          : 277.704
    Left Arm D1 momentum                      : 0.833989
    Left Arm D1 NMR                           : 0.30881
    Left Arm Q3 power supply current          : 331.976
    Left Arm Q3 momentum                      : 0.833861
    Left Arm Q3 gauss meter                   : -0.16548
    Left Arm Q3 power supply polarity         : 1
    Average current of the two cavities     : 4.95819
    Current on Unser monitor                : 13.4391
    Current on Upstream bcm                 : 4.96505
    Current on Downstream bcm               : 4.88338
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 73.7092
    MBSY1c Hall A Beam energy               : 835.372
    MBSY1c magnet current (amp)             : 34.4338
    MBSY1c Bdl                              : 208468
    MBSY3c Hall C Beam energy               : 2424.72
    Tiefenbach Hall A energy                : 0
    Tiefenbach Hall C energy                : 0
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : 0.0057877
    IPM1H04A.XPOS                           : -0.182823
    IPM1H04A.YPOS                           : 1.38087
    IPM1H04B.XPOS                           : -0.0545133
    IPM1H04B.YPOS                           : -0.0690826
    Right Arm Arm Collimator                 : 0.364014
    Left Arm Arm Collimator                   : 0.365967
     HacR_HPM_LVDT:VALr                     : -994
     HacR_VPM_LVDT:VALr                     : -656
     HacR_HPE1313A:0_Ch58                   : -0.540039
     HacR_HPE1313A:0_Ch55                   : 22.168
     HacR_HPE1313A:0_Ch54                   : -0.824219
     HacR_alignROLL                         : -0.344049
     HacR_alignPITCH                        : -0.0150327
     HacR_alignHPT                          : -1.67374
     HacL_HPM_LVDT:VALr                     : -6965
     HacL_VPM_LVDT:VALr                     : 1844
     HacL_HPE1313A:0_Ch58                   : -0.18457
     HacL_HPE1313A:0_Ch55                   : 23.5352
     HacL_HPE1313A:0_Ch54                   : -0.012207
     HacL_alignROLL                         : 0.330241
     HacL_alignPITCH                        : -0.100603
     HacL_alignHPT                          : 3.89085
    haBDSPOS                                 : 2.47884e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 62
    haL3_Fan_frequency_R                     : 25
    haH2_P_Fill_Target_R                     : 20.11
    haH2_P_Exhaust_R                         : 20.41
    haH2_P_Fill_Bottle_R                     : 20.15
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 18.33
    haD2_P_Fill_Bottle_R                     : 37.94
    haD2_DP_Fill_Exhaust_R                   : 0.0743
    haSC200_6_Sensor_1_R                     : 241.88
    haSC200_6_Sensor_2_R                     : 35.65
    haSC200_6_Sensor_3_R                     : 44.15
    haSC200_6_Sensor_4_R                     : 42.17
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.02
    haITC502_4_Sensor_1_R                    : 159.9
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 288.82
    haITC502_5_Sensor_2_R                    : 0
    haITC502_5_Sensor_3_R                    : 885.1
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 28.14
    Right Arm Arm Collimator                 : 0.363965
    Left Arm Arm Collimator                   : 0.366016
    Wien angle                               : 32.9201
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 739.73
    Wien field                               : 21.203
    Laser attenuation Hall A                 : 195
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF