User name adev
Log entry time 09:10:05 on April 25, 2001
Entry number 61326
keyword=Start_Run_3904_RunType=Other,Tar=absence,Rad=out,comment=4
Beginning-of-run EPICS data for Run Number 3904 at Wed Apr 25 09:09:52 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=9,ps2=9,ps3=9,ps4=9,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 704.725
Right Arm Q1 momentum : 0.937215
Right Arm Q1 gauss meter : 0.017749
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 0.265037
Right Arm Q2 momentum : 0.000615839
Right Arm Q2 gauss meter : 0.0006269
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 284.377
Right Arm D1 momentum : 0.833999
Right Arm D1 NMR : 0.309487
Right Arm Q3 power supply current : 0.0918457
Right Arm Q3 momentum : 0.000230821
Right Arm Q3 gauss meter : 0.0002674
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 704.305
Left Arm Q1 momentum : 0.936163
Left Arm Q1 gauss meter : 0.06017
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 0.261015
Left Arm Q2 momentum : 0.000606167
Left Arm Q2 gauss meter : 0.0011383
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 277.701
Left Arm D1 momentum : 0.833991
Left Arm D1 NMR : 0.30881
Left Arm Q3 power supply current : 1.89601
Left Arm Q3 momentum : 0.00476242
Left Arm Q3 gauss meter : -0.0001005
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 2.15603
Current on Unser monitor : 10.1677
Current on Upstream bcm : 2.11961
Current on Downstream bcm : 2.19246
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 70.1895
Beam energy : 835.372
MBSY1c magnet current (amp) : 34.4338
Radiator 5V Linear Supply : 5.02076
Radiator Encoder : 0.173382
haBDSPOS : 5.3284e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 63
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 242.36
haSC200_6_Sensor_2_R : 35.73
haSC200_6_Sensor_3_R : 44.37
haSC200_6_Sensor_4_R : 42.24
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 160
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 0
haITC502_5_Sensor_2_R : 0
haITC502_5_Sensor_3_R : 884.9
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.14
Right Arm Arm Collimator : 0.363965
Left Arm Arm Collimator : 0.365918
HacR_HPM_LVDT:VALr : -995
HacR_VPM_LVDT:VALr : -679
HacR_HPE1313A:0_Ch58 : -0.539062
HacR_HPE1313A:0_Ch55 : 22.3633
HacR_HPE1313A:0_Ch54 : -0.824219
HacR_alignROLL : -0.343818
HacR_alignPITCH : -0.0166448
HacR_alignHPT : -1.67275
HacL_HPM_LVDT:VALr : -6979
HacL_VPM_LVDT:VALr : 1826
HacL_HPE1313A:0_Ch58 : -0.182617
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : -0.0126953
HacL_alignROLL : 0.330623
HacL_alignPITCH : -0.101845
HacL_alignHPT : 3.90855
Right Arm Angle Floor Angle : 15
Right Arm Angle Vernier : -34.1
Right Arm Scattering Angle : 15.0118
Left Arm Angle Floor Angle : 15
Left Arm Angle Vernier : 30.8
Left Arm Scattering Angle : 14.972
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 145
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88