User name adev
Log entry time 10:28:55 on April 25, 2001
Entry number 61336
keyword=Start_Run_3909_RunType=Other,Tar=9foil-12C,Rad=out,comment=Q3
Beginning-of-run EPICS data for Run Number 3909 at Wed Apr 25 10:28:44 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=9,ps3=1,ps4=9,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 0.0001088
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 0.311903
Right Arm Q2 momentum : 0.000724736
Right Arm Q2 gauss meter : 0.0006214
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 284.376
Right Arm D1 momentum : 0.833999
Right Arm D1 NMR : 0.309487
Right Arm Q3 power supply current : 121.834
Right Arm Q3 momentum : 0.306185
Right Arm Q3 gauss meter : 0.05481
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0
Left Arm Q1 gauss meter : 0.0004963
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 0.270561
Left Arm Q2 momentum : 0.000628335
Left Arm Q2 gauss meter : 0.0011594
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 277.7
Left Arm D1 momentum : 0.833989
Left Arm D1 NMR : 0.30881
Left Arm Q3 power supply current : 121.941
Left Arm Q3 momentum : 0.306293
Left Arm Q3 gauss meter : -0.06029
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 2.3398
Current on Unser monitor : 13.4052
Current on Upstream bcm : 1.69517e-304
Current on Downstream bcm : 4.67959
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 72.2149
Beam energy : 835.372
MBSY1c magnet current (amp) : 34.4338
Radiator 5V Linear Supply : 5.0232
Radiator Encoder : 0.156288
haBDSPOS : 2.47884e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 64.5
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 242.46
haSC200_6_Sensor_2_R : 35.77
haSC200_6_Sensor_3_R : 44.44
haSC200_6_Sensor_4_R : 42.31
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 160
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 0
haITC502_5_Sensor_2_R : 88.47
haITC502_5_Sensor_3_R : 878
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.15
Right Arm Arm Collimator : 0.364014
Left Arm Arm Collimator : 0.365967
HacR_HPM_LVDT:VALr : -999
HacR_VPM_LVDT:VALr : -673
HacR_HPE1313A:0_Ch58 : -0.539062
HacR_HPE1313A:0_Ch55 : 22.3633
HacR_HPE1313A:0_Ch54 : -0.82373
HacR_alignROLL : -0.342832
HacR_alignPITCH : -0.0157471
HacR_alignHPT : -1.66883
HacL_HPM_LVDT:VALr : -6984
HacL_VPM_LVDT:VALr : 1839
HacL_HPE1313A:0_Ch58 : -0.182617
HacL_HPE1313A:0_Ch55 : 23.7305
HacL_HPE1313A:0_Ch54 : -0.012207
HacL_alignROLL : 0.330235
HacL_alignPITCH : -0.102356
HacL_alignHPT : 3.91432
Right Arm Angle Floor Angle : 15
Right Arm Angle Vernier : -34.1
Right Arm Scattering Angle : 15.0118
Left Arm Angle Floor Angle : 15
Left Arm Angle Vernier : 30.8
Left Arm Scattering Angle : 14.972
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 180
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88