User name adev
Log entry time 10:50:09 on April 25, 2001
Entry number 61338
keyword=Start_Run_3910_RunType=Other,Tar=9foil-12C,Rad=out,comment=Q1
Beginning-of-run EPICS data for Run Number 3910 at Wed Apr 25 10:49:56 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=10,ps2=999,ps3=10,ps4=999,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 696.885
Right Arm Q1 momentum : 0.926789
Right Arm Q1 gauss meter : 0.017546
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 0.282348
Right Arm Q2 momentum : 0.000656063
Right Arm Q2 gauss meter : 0.000602
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 284.381
Right Arm D1 momentum : 0.834002
Right Arm D1 NMR : 0.309488
Right Arm Q3 power supply current : 0.0571078
Right Arm Q3 momentum : 0.00014352
Right Arm Q3 gauss meter : 0.0002419
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 696.605
Left Arm Q1 momentum : 0.925928
Left Arm Q1 gauss meter : 0.05954
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 0.0204464
Left Arm Q2 momentum : 4.74835e-05
Left Arm Q2 gauss meter : 0.0011589
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 277.703
Left Arm D1 momentum : 0.83399
Left Arm D1 NMR : 0.30881
Left Arm Q3 power supply current : 1.86526
Left Arm Q3 momentum : 0.00469744
Left Arm Q3 gauss meter : -9.15e-05
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 5.07755
Current on Unser monitor : 13.5823
Current on Upstream bcm : 5.07104
Current on Downstream bcm : 5.08406
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 73.9787
Beam energy : 835.372
MBSY1c magnet current (amp) : 34.4338
Radiator 5V Linear Supply : 5.0232
Radiator Encoder : 0.161172
haBDSPOS : 2.47884e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62.5
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 242.13
haSC200_6_Sensor_2_R : 35.68
haSC200_6_Sensor_3_R : 44.25
haSC200_6_Sensor_4_R : 42.21
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 160
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 288.68
haITC502_5_Sensor_2_R : 0.05
haITC502_5_Sensor_3_R : 884.7
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.15
Right Arm Arm Collimator : 0.363965
Left Arm Arm Collimator : 0.366016
HacR_HPM_LVDT:VALr : -985
HacR_VPM_LVDT:VALr : -671
HacR_HPE1313A:0_Ch58 : -0.539062
HacR_HPE1313A:0_Ch55 : 22.2656
HacR_HPE1313A:0_Ch54 : -0.824707
HacR_alignROLL : -0.344484
HacR_alignPITCH : -0.0164455
HacR_alignHPT : -1.68133
HacL_HPM_LVDT:VALr : -6974
HacL_VPM_LVDT:VALr : 1846
HacL_HPE1313A:0_Ch58 : -0.182129
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.0117188
HacL_alignROLL : 0.33047
HacL_alignPITCH : -0.101698
HacL_alignHPT : 3.90304
Right Arm Angle Floor Angle : 15
Right Arm Angle Vernier : -34.1
Right Arm Scattering Angle : 15.0118
Left Arm Angle Floor Angle : 15
Left Arm Angle Vernier : 30.8
Left Arm Scattering Angle : 14.9721
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 100
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88