Log entry time 11:01:33 on April 25, 2001
Entry number 61340
keyword=Start_Run_3911_RunType=Other,Tar=9foil-12C,Rad=out,comment=Q1
Beginning-of-run EPICS data for Run Number 3911 at Wed Apr 25 11:01:22 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=10,ps2=999,ps3=10,ps4=999,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 634.235
Right Arm Q1 momentum : 0.843471
Right Arm Q1 gauss meter : 0.016003
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 0.138657
Right Arm Q2 momentum : 0.000322183
Right Arm Q2 gauss meter : 0.0005984
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 284.375
Right Arm D1 momentum : 0.833999
Right Arm D1 NMR : 0.309487
Right Arm Q3 power supply current : -0.0153245
Right Arm Q3 momentum : -3.85127e-05
Right Arm Q3 gauss meter : 0.0002418
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 634.025
Left Arm Q1 momentum : 0.842747
Left Arm Q1 gauss meter : 0.05428
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 0.243526
Left Arm Q2 momentum : 0.000565551
Left Arm Q2 gauss meter : 0.001121
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 277.705
Left Arm D1 momentum : 0.83399
Left Arm D1 NMR : 0.30881
Left Arm Q3 power supply current : 1.89069
Left Arm Q3 momentum : 0.00474906
Left Arm Q3 gauss meter : -9.94e-05
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 5.15743
Current on Unser monitor : 12.2872
Current on Upstream bcm : 5.1778
Current on Downstream bcm : 5.13705
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 74.2424
Beam energy : 835.372
MBSY1c magnet current (amp) : 34.4338
Radiator 5V Linear Supply : 5.02076
Radiator Encoder : 0.163614
haBDSPOS : 2.47884e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62.5
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 241.95
haSC200_6_Sensor_2_R : 35.63
haSC200_6_Sensor_3_R : 44.17
haSC200_6_Sensor_4_R : 42.16
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 160
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 87.82
haITC502_5_Sensor_2_R : 26.71
haITC502_5_Sensor_3_R : 2887.1
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.14
Right Arm Arm Collimator : 0.363916
Left Arm Arm Collimator : 0.365918
HacR_HPM_LVDT:VALr : -982
HacR_VPM_LVDT:VALr : -668
HacR_HPE1313A:0_Ch58 : -0.539551
HacR_HPE1313A:0_Ch55 : 22.2168
HacR_HPE1313A:0_Ch54 : -0.824219
HacR_alignROLL : -0.344542
HacR_alignPITCH : -0.0154815
HacR_alignHPT : -1.68577
HacL_HPM_LVDT:VALr : -6973
HacL_VPM_LVDT:VALr : 1848
HacL_HPE1313A:0_Ch58 : -0.183594
HacL_HPE1313A:0_Ch55 : 23.6328
HacL_HPE1313A:0_Ch54 : -0.012207
HacL_alignROLL : 0.329
HacL_alignPITCH : -0.102061
HacL_alignHPT : 3.89815
Right Arm Angle Floor Angle : 15
Right Arm Angle Vernier : -34.1
Right Arm Scattering Angle : 15.0119
Left Arm Angle Floor Angle : 15
Left Arm Angle Vernier : 30.8
Left Arm Scattering Angle : 14.9721
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 100
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88