User name adev
Log entry time 13:40:36 on April 25, 2001
Entry number 61346
keyword=Start_Run_3914_RunType=Other,Tar=carbon,Rad=out,comment=Q12
Beginning-of-run EPICS data for Run Number 3914 at Wed Apr 25 13:40:26 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=2000,ps3=1,ps4=2000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 0.0001042
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 291.515
Right Arm Q2 momentum : 0.677364
Right Arm Q2 gauss meter : 0.15344
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 284.375
Right Arm D1 momentum : 0.834
Right Arm D1 NMR : 0.309487
Right Arm Q3 power supply current : 0.152595
Right Arm Q3 momentum : 0.000383491
Right Arm Q3 gauss meter : 0.0002361
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0
Left Arm Q1 gauss meter : 0.0004112
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 291.341
Left Arm Q2 momentum : 0.676594
Left Arm Q2 gauss meter : 0.1542
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 277.705
Left Arm D1 momentum : 0.833987
Left Arm D1 NMR : 0.308809
Left Arm Q3 power supply current : 1.89722
Left Arm Q3 momentum : 0.00476547
Left Arm Q3 gauss meter : -0.0001058
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 5.94302
Current on Unser monitor : 13.5439
Current on Upstream bcm : 6.00327
Current on Downstream bcm : 6.02408
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 74.1177
Beam energy : 835.372
MBSY1c magnet current (amp) : 34.4338
Radiator 5V Linear Supply : 5.02076
Radiator Encoder : 0.163614
haBDSPOS : 682850
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 63.5
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 241.91
haSC200_6_Sensor_2_R : 35.67
haSC200_6_Sensor_3_R : 44.15
haSC200_6_Sensor_4_R : 42.17
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 160
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 26.93
haITC502_5_Sensor_2_R : 289.77
haITC502_5_Sensor_3_R : 0
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.31
Right Arm Arm Collimator : 0.363916
Left Arm Arm Collimator : 0.366016
HacR_HPM_LVDT:VALr : -964
HacR_VPM_LVDT:VALr : -653
HacR_HPE1313A:0_Ch58 : -0.539062
HacR_HPE1313A:0_Ch55 : 22.2168
HacR_HPE1313A:0_Ch54 : -0.823242
HacR_alignROLL : -0.343006
HacR_alignPITCH : -0.0159967
HacR_alignHPT : -1.70679
HacL_HPM_LVDT:VALr : -6996
HacL_VPM_LVDT:VALr : 1863
HacL_HPE1313A:0_Ch58 : -0.182129
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.0126953
HacL_alignROLL : 0.329464
HacL_alignPITCH : -0.102497
HacL_alignHPT : 3.92587
Right Arm Angle Floor Angle : 15
Right Arm Angle Vernier : -34.1
Right Arm Scattering Angle : 15.012
Left Arm Angle Floor Angle : 15
Left Arm Angle Vernier : 30.8
Left Arm Scattering Angle : 14.9719
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 160
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88