User name adev
Log entry time 16:05:10 on May 23, 2001
Entry number 61417
keyword=Start_Run_1015_RunType=Pulser,Tar=absence,Rad=out,comment=Q3
Beginning-of-run EPICS data for Run Number 1015 at Wed May 23 16:04:46 EDT 2001
; LEFT SPECTROMETER
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps3=1,ps4=1,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 4.88e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.26288
Right Arm Q2 momentum : 0.000610826
Right Arm Q2 gauss meter : -0.0003708
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.64603
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.501163
Right Arm Q3 power supply current : -0.0167958
Right Arm Q3 momentum : -4.22102e-05
Right Arm Q3 gauss meter : -1.19e-05
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1e+06
Left Arm Q1 momentum : 1329.2
Left Arm Q1 gauss meter : 0.000325
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 0.18666
Left Arm Q2 momentum : 0.000433489
Left Arm Q2 gauss meter : 0.0002034
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 0.130366
Left Arm D1 momentum : 0
Left Arm D1 NMR : 0.422226
Left Arm Q3 power supply current : 0.000183426
Left Arm Q3 momentum : 7.99229e-07
Left Arm Q3 gauss meter : 0.0006927
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0
Current on Unser monitor : 5.73907
Current on Upstream bcm : 0
Current on Downstream bcm : 0
Upstream Cavity Coefficient : 0
Downstream Cavity Coefficient : 0
Current on IBC0L02 (source) : 0.00143682
Beam energy : 1224.51
MBSY1c magnet current (amp) : 50.7628
Radiator 5V Linear Supply : 0.00976801
Radiator Encoder : 0
haBDSPOS : 0
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 241.81
haSC200_6_Sensor_2_R : 14.51
haSC200_6_Sensor_3_R : 47.28
haSC200_6_Sensor_4_R : 41.81
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 0
haITC502_1_Sensor_2_R : 0
haITC502_1_Sensor_3_R : 0
haITC502_4_Sensor_1_R : 0
haITC502_4_Sensor_2_R : 0
haITC502_4_Sensor_3_R : 0
haITC502_5_Sensor_1_R : 0
haITC502_5_Sensor_2_R : 0
haITC502_5_Sensor_3_R : 0
haITC502_6_Sensor_1_R : 0
haITC502_6_Sensor_2_R : 0
haITC502_6_Sensor_3_R : 0
Right Arm Arm Collimator : 0.363818
Left Arm Arm Collimator : 0.868945
HacR_HPM_LVDT:VALr : 3292
HacR_VPM_LVDT:VALr : 3855
HacR_HPE1313A:0_Ch58 : -0.521484
HacR_HPE1313A:0_Ch55 : 22.4609
HacR_HPE1313A:0_Ch54 : -0.801758
HacR_alignROLL : -0.322506
HacR_alignPITCH : -0.0324871
HacR_alignHPT : -6.4803
HacL_HPM_LVDT:VALr : 3448
HacL_VPM_LVDT:VALr : 3684
HacL_HPE1313A:0_Ch58 : -0.128418
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : -0.138184
HacL_alignROLL : 0
HacL_alignPITCH : 0
HacL_alignHPT : 0
Right Arm Angle Floor Angle : 15
Right Arm Angle Vernier : -34.1
Right Arm Scattering Angle : 15.0444
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : 0
Wien angle : 32.9201
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 739.73
Wien field : 21.203
Laser attenuation Hall A : 150
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : 0
Survey Y offset bpmA : 0
Survey X offset bpmB : 0
Survey Y offset bpmB : 0