• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 03:34:52 on June 4, 2001

    Entry number 61726

    keyword=Start_Run_20328,Run_type=optics,beam_energy=1.1964,beam_halfwaveplate=in,beam_polarization=80.0,beam_raster=off,comment_text=beam alignment,daq_mode=single,leftarm_p=1190.3,leftarm_theta=20,rightarm_p=1190.3,rightarm_theta=20,target_halfwaveplate=out,target_name=Gore,target_polarization=45.0,target_type=BeO Carbon foils
    Beginning-of-run EPICS data for Run Number 20328 at Mon Jun 4 03:34:25 EDT 2001
    ; RIGHT SPECTROMETER
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string.
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 to measure efficiency
    ;
    ps1=1,ps2=10000,ps8=65535
    
    
    Right Arm Q1 power supply current : 895.125
    Right Arm Q1 momentum : 1.19043
    Right Arm Q1 gauss meter : -0.022345
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 512.305
    Right Arm Q2 momentum : 1.19039
    Right Arm Q2 gauss meter : 0.2693
    Right Arm Q2 power supply polarity : 0
    Right Arm D1 power supply current : 408.596
    Right Arm D1 momentum : 1.1903
    Right Arm D1 NMR : 0.441706
    Right Arm Q3 power supply current : 473.605
    Right Arm Q3 momentum : 1.19024
    Right Arm Q3 gauss meter : 0.2122
    Right Arm Q3 power supply polarity : 1
    Left Arm Q1 power supply current : 895.265
    Left Arm Q1 momentum : 1.18999
    Left Arm Q1 gauss meter : -0.0757
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 512.602
    Left Arm Q2 momentum : 1.19044
    Left Arm Q2 gauss meter : 0.2707
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 398.033
    Left Arm D1 momentum : 1.19031
    Left Arm D1 NMR : 0.440637
    Left Arm Q3 power supply current : 473.943
    Left Arm Q3 momentum : 1.19046
    Left Arm Q3 gauss meter : -0.2367
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 5.1419
    Current on Unser monitor : 10.8224
    Current on Upstream bcm : 5.10891
    Current on Downstream bcm : 5.1749
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) : CAC: UDP send error = "Connection refused"
    Beam energy : 1197.33
    MBSY1c magnet current (amp) : 49.6222
    Radiator 5V Linear Supply : 0
    Radiator Encoder : 0
    haBDSPOS : 0
    haL1_Fan_frequency_R : 0
    haL2_Fan_frequency_R : 0
    haL3_Fan_frequency_R : 0
    haSC200_6_Sensor_1_R : 242.95
    haSC200_6_Sensor_2_R : 14.64
    haSC200_6_Sensor_3_R : 48.96
    haSC200_6_Sensor_4_R : 42.09
    haHe_Omega_DPG_Sensor_R : 0#
    haITC502_1_Sensor_1_R : 0
    haITC502_1_Sensor_2_R : 0
    haITC502_1_Sensor_3_R : 0
    haITC502_4_Sensor_1_R : 0
    haITC502_4_Sensor_2_R : 0
    haITC502_4_Sensor_3_R : 0
    haITC502_5_Sensor_1_R : 0
    haITC502_5_Sensor_2_R : 0
    haITC502_5_Sensor_3_R : 0
    haITC502_6_Sensor_1_R : 0
    haITC502_6_Sensor_2_R : 0
    haITC502_6_Sensor_3_R : 0
    Right Arm Arm Collimator : 0.865527
    Left Arm Arm Collimator : 0.868848
    HacR_HPM_LVDT:VALr :
    HacR_VPM_LVDT:VALr :
    HacR_HPE1313A:0_Ch58 : -0.512695
    HacR_HPE1313A:0_Ch55 : 23.584
    HacR_HPE1313A:0_Ch54 : -0.779785
    HacR_alignROLL : -0.247489
    HacR_alignPITCH : 0.0751075
    HacR_alignHPT : 0
    HacL_HPM_LVDT:VALr :
    HacL_VPM_LVDT:VALr :
    HacL_HPE1313A:0_Ch58 : -0.124512
    HacL_HPE1313A:0_Ch55 : 24.4629
    HacL_HPE1313A:0_Ch54 : -0.151367
    HacL_alignROLL : 0.0480679
    HacL_alignPITCH : 0.161884
    HacL_alignHPT : 0
    Right Arm Angle Floor Angle : 20
    Right Arm Angle Vernier : -34
    Right Arm Scattering Angle : 22.3474
    Left Arm Angle Floor Angle : 20
    Left Arm Angle Vernier : 31
    Left Arm Scattering Angle : 19.5151
    Wien angle :
    Helicity Mode ON/OFF Random/Toggle :
    Wien BDL :
    Wien field : CAC: UDP send error = "Connection refused"
    Laser attenuation Hall A : CAC: UDP send error = "Connection refused"
    Laser power Hall A :
    Half-wave plate (off=out) :
    Survey X offset bpmA : -0.32
    Survey Y offset bpmA : -0.35
    Survey X offset bpmB : -0.05
    Survey Y offset bpmB : -0.88