    User name adev

    Log entry time 05:45:36 on June 4, 2001

    Entry number 61756

    keyword=End_of_Run_1334
    ****************************
     Run Number: 1334
     End of Run Comment:
    Run_type=optics,beam_energy=1.1964,beam_halfwaveplate=in,beam_polarization=80.0,beam_raster=off,comment_text=sieve slit in,daq_mode=two daq,leftarm_p=1190.3,leftarm_theta=20,rightarm_p=1190.30,rightarm_theta=20,target_halfwaveplate=out,target_name=GORE,target_polarization=45.0,target_type=BeO Carbon foils
     
    
    PRESCALE FACTORS:ps3=1   ps4=10000   ps8=65535   
    
    TIME [0]:  11.7 mins  [+]:   5.8 mins  [-]:   5.8 mins  
    LIVE [0]:  98.11%     [+]:  98.14%     [-]:  98.08%     
    
    TRIGGER RATES:
    T3[0] [PRESC/REAL]:0.0976/0.0976 kHz	T4[0] [PRESC/REAL]:0.0000/0.0311 kHz	
    T3[+] [PRESC/REAL]:0.0966/0.0966 kHz	T4[+] [PRESC/REAL]:0.0000/0.0310 kHz	
    T3[-] [PRESC/REAL]:0.0985/0.0985 kHz	T4[-] [PRESC/REAL]:0.0000/0.0311 kHz	
    
    APPROXIMATE CHARGE ASYMMETRIES
    BCM u1 :     6528 ppm     BCM u3 :     6376 ppm     BCM u10:     6490 ppm     
    BCM d1 :     6575 ppm     BCM d3 :     6191 ppm     BCM d10:     6408 ppm     
    
    APPROXIMATE BCM CHARGES
    BCM u1 [0]:2.246          BCM u3 [0]:2.245          BCM u10[0]:2.247          
    BCM u1 [+]:0.544          BCM u3 [+]:0.544          BCM u10[+]:0.5443         
    BCM u1 [-]:0.5511         BCM u3 [-]:0.551          BCM u10[-]:0.5515         
    
    BCM d1 [0]:2.276          BCM d3 [0]:2.29           BCM d10[0]:2.291          
    BCM d1 [+]:0.5513         BCM d3 [+]:0.555          BCM d10[+]:0.555          
    BCM d1 [-]:0.5586         BCM d3 [-]:0.5619         BCM d10[-]:0.5621         
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1334 at Mon Jun 4 05:45:10 EDT 2001
    Right Arm D1 momentum : 1.19028
    Right Arm arm angle : 22.3474
    Left Arm D1 momentum : 1.12877
    Left Arm arm angle : 19.5151
    Tiefenbach Hall A energy : 1196.38
    Right Arm arm mispointing (HPT) : 0
    Left Arm arm mispointing (HPT) : 0
    Right Arm Q1 power supply current : 836.115
    Right Arm Q1 momentum : 1.11195
    Right Arm Q1 gauss meter : 0
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 478.498
    Right Arm Q2 momentum : 1.11184
    Right Arm Q2 gauss meter : 0.2514
    Right Arm Q2 power supply polarity : 0
    Right Arm D1 power supply current : 409.045
    Right Arm D1 momentum : 1.19043
    Right Arm D1 NMR : 0.441755
    Right Arm Q3 power supply current : 442.303
    Right Arm Q3 momentum : 1.11157
    Right Arm Q3 gauss meter : 0.19816
    Right Arm Q3 power supply polarity : 1
    Left Arm Q1 power supply current : 836.22
    Left Arm Q1 momentum : 1.1115
    Left Arm Q1 gauss meter : -0.0707
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 478.799
    Left Arm Q2 momentum : 1.11193
    Left Arm Q2 gauss meter : 0.2529
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 368.061
    Left Arm D1 momentum : 1.11258
    Left Arm D1 NMR : 0.41189
    Left Arm Q3 power supply current : 442.699
    Left Arm Q3 momentum : 1.11198
    Left Arm Q3 gauss meter : -0.2211
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 4.9981
    Current on Unser monitor : 10.0225
    Current on Upstream bcm : 4.96967
    Current on Downstream bcm : 5.02654
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) : 4.95852
    MBSY1c Hall A Beam energy : 1197.33
    MBSY1c magnet current (amp) : 49.6222
    MBSY1c Bdl : 298794
    MBSY3c Hall C Beam energy : 21.1371
    Tiefenbach Hall A energy : 1196.38
    Tiefenbach Hall C energy : 20.656
    Delta(E)/E width (MV_AI_DXWID) : 3.60495
    IPM1C12.XPOS : -0.00216624
    IPM1H04A.XPOS : 2.72422
    IPM1H04A.YPOS : -1.29095
    IPM1H04B.XPOS : 1.4089
    IPM1H04B.YPOS : -0.226208
    Right Arm Arm Collimator : 0.363818
    Left Arm Arm Collimator : 0.366064
    HacR_HPE1313A:0_Ch58 : -0.513184
    HacR_HPE1313A:0_Ch55 : 23.584
    HacR_HPE1313A:0_Ch54 : -0.780273
    HacR_alignROLL : -0.248534
    HacR_alignPITCH : 0.0750405
    HacR_alignHPT : 0
    HacL_HPE1313A:0_Ch58 : -0.125
    HacL_HPE1313A:0_Ch55 : 24.4629
    HacL_HPE1313A:0_Ch54 : -0.151855
    HacL_alignROLL : 0.047626
    HacL_alignPITCH : 0.161447
    HacL_alignHPT : 0
    haBDSPOS : 0
    haL1_Fan_frequency_R : 0
    haL2_Fan_frequency_R : 0
    haL3_Fan_frequency_R : 0
    haH2_P_Fill_Target_R : 0
    haH2_P_Exhaust_R : 0
    haH2_P_Fill_Bottle_R : 0
    haH2_DP_Fill_Exhaust_R : 0
    haD2_P_Fill_Target_R : 0
    haD2_P_Exhaust_R : 0
    haD2_P_Fill_Bottle_R : 0
    haD2_DP_Fill_Exhaust_R : 0.0742
    haSC200_6_Sensor_1_R : 242.9
    haSC200_6_Sensor_2_R : 14.64
    haSC200_6_Sensor_3_R : 48.91
    haSC200_6_Sensor_4_R : 42.04
    haHe_Omega_DPG_Sensor_R : 0#
    haITC502_1_Sensor_1_R : 0
    haITC502_1_Sensor_2_R : 0
    haITC502_1_Sensor_3_R : 0
    haITC502_2_Sensor_1_R : 0
    haITC502_2_Sensor_2_R : 0
    haITC502_2_Sensor_3_R : 0
    haITC502_4_Sensor_1_R : 0
    haITC502_4_Sensor_2_R : 0
    haITC502_4_Sensor_3_R : 0
    haITC502_5_Sensor_1_R : 0
    haITC502_5_Sensor_2_R : 0
    haITC502_5_Sensor_3_R : 0
    haITC502_6_Sensor_1_R : 0
    haITC502_6_Sensor_2_R : 0
    haITC502_6_Sensor_3_R : 0
    Right Arm Arm Collimator : 0.36377
    Left Arm Arm Collimator : 0.366064
    Wien angle : 16.4851
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 345.97
    Wien field : 10.158
    Laser attenuation Hall A : 200
    Laser power Hall A : 57
    Half-wave plate (off=out) : ON
    Polarized 3He Target RTD #1 : 46.709
    Polarized 3He Target RTD #2 : 46.4844
    Polarized 3He Target RTD #3 : 51.6797
    Polarized 3He Target RTD #4 : 48.8672
    Polarized 3He Target RTD #5 : 48.5645
    Polarized 3He Target RTD #6 : 208.535
    Polarized 3He Target RTD #7 : 200.039
    Polarized 3He Target RTD #7 : 200.039
    Polarized 3He Target Ref. Cell : -1.33948
    Polarized 3He Target Ref. Cell : 799.332
    Polarized 3He Target Cooling Jet : 33.2373
    Polarized 3He Target Half-Wave Plate DIST: 1.2e+06
    Polarized 3He Target Half-Wave Plate STAT: CALC
    Polarized 3He Target Position (PA) : 70.2095
    Polarized 3He Target Position (POS) : BeO+12C Foils
    Polarized 3He Target Position (DA) : 70.2095
    Polarized 3He Target Position (SS9) : Axis is OK
    Polarized 3He Target Position (SA10) : 0
    Polarized 3He Target Position (SA9) : 0
    Polarized 3He Laser#1 State : 0
    Polarized 3He Laser#1 Current : 38
    Polarized 3He Laser#1 Temperature : 14
    Polarized 3He Laser#2 State : 0
    Polarized 3He Laser#2 Current : 37
    Polarized 3He Laser#2 Temperature : 23
    Polarized 3He Laser#3 State : 0
    Polarized 3He Laser#3 Current : 40
    Polarized 3He Laser#3 Temperature : 26.4
    Polarized 3He Laser#4 State : 2
    Polarized 3He Laser#4 Current : 40
    Polarized 3He Laser#4 Temperature : 15
    Polarized 3He Laser#5 State :
    Polarized 3He Laser#5 Current :
    Polarized 3He Laser#5 Temperature :
    Polarized 3He Laser#6 State : 2
    Polarized 3He Laser#6 Current : 40
    Polarized 3He Laser#6 Temperature : 14
    Polarized 3He Laser#7 State : 2
    Polarized 3He Laser#7 Current : 36500
    Polarized 3He Laser#7 Temperature : 18.5