• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 15:02:56 on June 6, 2001

    Entry number 62110

    keyword=Start_Run_20401,Run_type=other,beam_energy=1.197,beam_halfwaveplate=in,beam_polarization=80.0,beam_raster=off,comment_text=False Asymmetry Study,daq_mode=one HRS daq,leftarm_p=1191.4,leftarm_theta=20,rightarm_p=1191.4,rightarm_theta=20,target_halfwaveplate=out,target_name=Gore,target_polarization=36,target_type=BeO Carbon foils
    Beginning-of-run EPICS data for Run Number 20401 at Wed Jun 6 15:02:38 EDT 2001
    ; RIGHT SPECTROMETER
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string.
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 to measure efficiency
    ;
    ps1=1,ps2=1,ps8=65535
    
    
     Right Arm Q1 power supply current : 895.825
    Right Arm Q1 momentum : 1.19136
    Right Arm Q1 gauss meter : -0.022361
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 512.544
    Right Arm Q2 momentum : 1.19095
    Right Arm Q2 gauss meter : 0.2695
    Right Arm Q2 power supply polarity : 0
    Right Arm D1 power supply current : 408.879
    Right Arm D1 momentum : 1.1914
    Right Arm D1 NMR : 0.442114
    Right Arm Q3 power supply current : 474.13
    Right Arm Q3 momentum : 1.19155
    Right Arm Q3 gauss meter : 0.2125
    Right Arm Q3 power supply polarity : 1
    Left Arm Q1 power supply current : 896.07
    Left Arm Q1 momentum : 1.19106
    Left Arm Q1 gauss meter : -0.07576
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 512.931
    Left Arm Q2 momentum : 1.1912
    Left Arm Q2 gauss meter : 0.271
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 398.59
    Left Arm D1 momentum : 1.19141
    Left Arm D1 NMR : 0.441044
    Left Arm Q3 power supply current : 474.204
    Left Arm Q3 momentum : 1.19111
    Left Arm Q3 gauss meter : -0.2369
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 4.06184
    Current on Unser monitor : 9.24604
    Current on Upstream bcm : 3.49474
    Current on Downstream bcm : 3.54663
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) :
    Beam energy : 1197.33
    MBSY1c magnet current (amp) : 49.6221
    Radiator 5V Linear Supply : 0.00488401
    Radiator Encoder : 0
    Right Arm Arm Collimator : 0.865674
    Left Arm Arm Collimator :
    HacR_HPE1313A:0_Ch58 : -0.510742
    HacR_HPE1313A:0_Ch55 : 23.6816
    HacR_HPE1313A:0_Ch54 : -0.777832
    HacR_alignROLL : -0.245832
    HacR_alignPITCH : 0.076656
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.124512
    HacL_HPE1313A:0_Ch55 : 24.6094
    HacL_HPE1313A:0_Ch54 : -0.155273
    HacL_alignROLL : 0.0447521
    HacL_alignPITCH : 0.162544
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 20
    Right Arm Angle Vernier : -34
    Right Arm Scattering Angle : 20.0018
    Left Arm Angle Floor Angle : 20
    Left Arm Angle Vernier : 31.2
    Left Arm Scattering Angle : 20.0051
    Wien angle :
    Helicity Mode ON/OFF Random/Toggle :
    Wien BDL :
    Wien field :
    Laser attenuation Hall A :
    Laser power Hall A :
    Half-wave plate (off=out) :
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.769
    Survey Y offset bpmB : -1