    User name adev

    Log entry time 14:02:41 on June 1, 2001

    Entry number 61594

    keyword=End_of_Run_1083
    End-of-run EPICS data for Run Number 1083 at Fri Jun 1 14:02:22 EDT 2001
    Right Arm D1 momentum : 0
    Right Arm arm angle : 22.5679
    Left Arm D1 momentum : 0
    Left Arm arm angle : 19.5151
    Tiefenbach Hall A energy : 5737.76
    Right Arm arm mispointing (HPT) : 0
    Left Arm arm mispointing (HPT) : 0
    Right Arm Q1 power supply current : 1e+06
    Right Arm Q1 momentum : 1329.9
    Right Arm Q1 gauss meter : -6.9e-06
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 0.107096
    Right Arm Q2 momentum : 0.000248849
    Right Arm Q2 gauss meter : -0.0001446
    Right Arm Q2 power supply polarity : 0
    Right Arm D1 power supply current : 1.97898
    Right Arm D1 momentum : 0
    Right Arm D1 NMR : 0.365959
    Right Arm Q3 power supply current : 0.230658
    Right Arm Q3 momentum : 0.000579676
    Right Arm Q3 gauss meter : -0.0001072
    Right Arm Q3 power supply polarity : 1
    Left Arm Q1 power supply current : 0
    Left Arm Q1 momentum : 0
    Left Arm Q1 gauss meter : 0.0001908
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 0.156298
    Left Arm Q2 momentum : 0.000362977
    Left Arm Q2 gauss meter : 0.0003325
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1.09517
    Left Arm D1 momentum : 0
    Left Arm D1 NMR : 0.156944
    Left Arm Q3 power supply current : 1.85096
    Left Arm Q3 momentum : 0.00464926
    Left Arm Q3 gauss meter : 0.000631
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 0
    Current on Unser monitor : 7.05661
    Current on Upstream bcm : 0
    Current on Downstream bcm : 0
    Upstream Cavity Coefficient : 0
    Downstream Cavity Coefficient : 0
    Current on IBC0L02 (source) : 0.00143682
    MBSY1c Hall A Beam energy : 5749.64
    MBSY1c magnet current (amp) : 0.0377197
    MBSY1c Bdl : 1.43483e+06
    MBSY3c Hall C Beam energy : 21.1371
    Tiefenbach Hall A energy : 5737.76
    Tiefenbach Hall C energy : 20.656
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Right Arm Arm Collimator : 0.363672
    Left Arm Arm Collimator : 0.868896
    HacR_HPM_LVDT:VALr :
    HacR_VPM_LVDT:VALr :
    HacR_HPE1313A:0_Ch58 : -0.513184
    HacR_HPE1313A:0_Ch55 : 23.4375
    HacR_HPE1313A:0_Ch54 : -0.780762
    HacR_alignROLL : -0.249697
    HacR_alignPITCH : 0.0748395
    HacR_alignHPT : 0
    HacL_HPM_LVDT:VALr :
    HacL_VPM_LVDT:VALr :
    HacL_HPE1313A:0_Ch58 : -0.123047
    HacL_HPE1313A:0_Ch55 : 24.4629
    HacL_HPE1313A:0_Ch54 : -0.147461
    HacL_alignROLL : 0.0516035
    HacL_alignPITCH : 0.163194
    HacL_alignHPT : 0
    haBDSPOS : 0
    haL1_Fan_frequency_R : 0
    haL2_Fan_frequency_R : 0
    haL3_Fan_frequency_R : 0
    haH2_P_Fill_Target_R : 0
    haH2_P_Exhaust_R : 0
    haH2_P_Fill_Bottle_R : 0
    haH2_DP_Fill_Exhaust_R : 0
    haD2_P_Fill_Target_R : 0
    haD2_P_Exhaust_R : 0
    haD2_P_Fill_Bottle_R : 0
    haD2_DP_Fill_Exhaust_R : 0.0741
    haSC200_6_Sensor_1_R : 242.56
    haSC200_6_Sensor_2_R : 14.56
    haSC200_6_Sensor_3_R : 48.47
    haSC200_6_Sensor_4_R : 41.96
    haHe_Omega_DPG_Sensor_R : 0#
    haITC502_1_Sensor_1_R : 0
    haITC502_1_Sensor_2_R : 0
    haITC502_1_Sensor_3_R : 0
    haITC502_2_Sensor_1_R : 0
    haITC502_2_Sensor_2_R : 0
    haITC502_2_Sensor_3_R : 0
    haITC502_4_Sensor_1_R : 0
    haITC502_4_Sensor_2_R : 0
    haITC502_4_Sensor_3_R : 0
    haITC502_5_Sensor_1_R : 0
    haITC502_5_Sensor_2_R : 0
    haITC502_5_Sensor_3_R : 0
    haITC502_6_Sensor_1_R : 0
    haITC502_6_Sensor_2_R : 0
    haITC502_6_Sensor_3_R : 0
    Right Arm Arm Collimator : 0.363672
    Left Arm Arm Collimator : 0.868945
    Wien angle : 16.4851
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 347.28
    Wien field : 10.158
    Laser attenuation Hall A : 200
    Laser power Hall A : 57
    Half-wave plate (off=out) : OFF
    

    06 Polarized 3He Target Half-Wave Plate STAT: NO_ALARM Polarized 3He Target Position (PA) : -0.3887 Polarized 3He Target Position (POS) : Empty Target Polarized 3He Target Position (DA) : -0.3888 Polarized 3He Target Position (SS9) : Axis is OK Polarized 3He Target Position (SA10) : 0 Polarized 3He Target Position (SA9) : 0 Polarized 3He Laser#1 State : 0 Polarized 3He Laser#1 Current : 0 Polarized 3He Laser#1 Temperature : 0 Polarized 3He Laser#2 State : 0 Polarized 3He Laser#2 Current : 0 Polarized 3He Laser#2 Temperature : 0 Polarized 3He Laser#3 State : 0 Polarized 3He Laser#3 Current : 0 Polarized 3He Laser#3 Temperature : 0 Polarized 3He Laser#4 State : 2 Polarized 3He Laser#4 Current : 0 Polarized 3He Laser#4 Temperature : 0 Polarized 3He Laser#5 State : 13 Polarized 3He Laser#5 Current : 0 Polarized 3He Laser#5 Temperature : 0 Polarized 3He Laser#6 State : 2 Polarized 3He Laser#6 Current : 0 Polarized 3He Laser#6 Temperature : 0 Polarized 3He Laser#7 State : 2 Polarized 3He Laser#7 Current : 0 Polarized 3He Laser#7 Temperature : 0 Polarized 3He Coil Current Longitudinal : Polarized 3He Coil Current Transverse :