Main INDEX
Monthly INDEX
PREV
NEXT
User name jpchen
Log entry time 00:06:42 on June 7,2001
Entry number 62282
keyword=Swing Shift summary
16:00 Beam was centered on BPMB at -2.75mm, -2.75mm, but not
on BPMA. The previous shift asked for tuning, but MCC is busy with
figure out why can not go higher than 8 uA. We took some 12C data
to for checking.
17:00 MCC decided to change laser to diode.
18:00-18:40 started tuning beam back, checking BeO, centered at -3mm on all BPM(A, B/ X,Y). Checked raster, adjusted to 4mm.
18:40-19:00 Tried to start charge asymmetry test, MCC asked to take beam away to
calibrate BCMs so they can deliver 15 uA.
19:00 MCC got us 15 uA. started charge asymmetry test (Joe and Antonin)
and also started data taking for C12 fale asymmetry run.
19:20 After 15 minutes beam, RF dropped off.
20:30 beam back. Started charge asymmetry and 12C false asymmetry data taking.
Problem with right arm deadtime (DAQ).
22:30 Completed cahrge asymmetry and 12C false asymmety study data taking.
23:00 Completed mini current calibration.
24:00 still doing N2 false asymmetry study.
current : 474.081
Right Arm Q3 momentum : 1.19121
Right Arm Q3 gauss meter : 0.2124
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 896.245
Left Arm Q1 momentum : 1.19129
Left Arm Q1 gauss meter : -0.07577
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 512.959
Left Arm Q2 momentum : 1.19127
Left Arm Q2 gauss meter : 0.2709
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 398.558
Left Arm D1 momentum : 1.19139
Left Arm D1 NMR : 0.441037
Left Arm Q3 power supply current : 474.223
Left Arm Q3 momentum : 1.19116
Left Arm Q3 gauss meter : -0.2369
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0255631
Current on Unser monitor : 5.43809
Current on Upstream bcm : 0.027469
Current on Downstream bcm : 0.0236572
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 0.00143682
Beam energy : 1197.33
MBSY1c magnet current (amp) : 0.0377197
Radiator 5V Linear Supply : 0.00488401
Radiator Encoder : 0
Right Arm Arm Collimator : 0.865723
Left Arm Arm Collimator : 0.868701
HacR_HPE1313A:0_Ch58 : -0.511719
HacR_HPE1313A:0_Ch55 : 23.7305
HacR_HPE1313A:0_Ch54 : -0.777832
HacR_alignROLL : -0.245891
HacR_alignPITCH : 0.0765889
HacR_alignHPT : -0
HacL_HPE1313A:0_Ch58 : -0.125488
HacL_HPE1313A:0_Ch55 : 24.6094
HacL_HPE1313A:0_Ch54 : -0.154785
HacL_alignROLL : 0.0451941
HacL_alignPITCH : 0.161234
HacL_alignHPT : -0
Right Arm Angle Floor Angle : 20
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 20.0018
Left Arm Angle Floor Angle : 20
Left Arm Angle Vernier : 31.2
Left Arm Scattering Angle : 20.005
Wien angle : 16.4851
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 345.97
Wien field : 10.158
Laser attenuation Hall A : 540
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.769
Survey Y offset bpmB : -1