• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 21:54:35 on June 5, 2001

    Entry number 62012

    keyword=Start_Run_20381,Run_type=elastic,beam_energy=1.197,beam_halfwaveplate=in,beam_polarization=80.0,beam_raster=off,comment_text=test run,daq_mode=one HRS daq,leftarm_p=1191.4,leftarm_theta=20,rightarm_p=1191.4,rightarm_theta=20,target_halfwaveplate=out,target_name=Gore,target_polarization=45.0,target_type=BeO Carbon foils
    Beginning-of-run EPICS data for Run Number 20381 at Tue Jun 5 21:54:16 EDT 2001
    ; RIGHT SPECTROMETER
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string.
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 to measure efficiency
    ;
    ps1=3,ps2=3,ps8=65535
    
    
     Right Arm Q1 power supply current : 895.755
    Right Arm Q1 momentum : 1.19127
    Right Arm Q1 gauss meter : -0.022354
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 512.852
    Right Arm Q2 momentum : 1.19166
    Right Arm Q2 gauss meter : 0.2696
    Right Arm Q2 power supply polarity : 0
    Right Arm D1 power supply current : 408.856
    Right Arm D1 momentum : 1.1914
    Right Arm D1 NMR : 0.442114
    Right Arm Q3 power supply current : 474.105
    Right Arm Q3 momentum : 1.19149
    Right Arm Q3 gauss meter : 0.2125
    Right Arm Q3 power supply polarity : 1
    Left Arm Q1 power supply current : 896.245
    Left Arm Q1 momentum : 1.19129
    Left Arm Q1 gauss meter : -0.07576
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 513.069
    Left Arm Q2 momentum : 1.19152
    Left Arm Q2 gauss meter : 0.2709
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 398.558
    Left Arm D1 momentum : 1.19139
    Left Arm D1 NMR : 0.441036
    Left Arm Q3 power supply current : 474.322
    Left Arm Q3 momentum : 1.19141
    Left Arm Q3 gauss meter : -0.2369
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 0.0260875
    Current on Unser monitor : 5.85876
    Current on Upstream bcm : 0.028682
    Current on Downstream bcm : 0.023493
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) :
    Beam energy : 1197.33
    MBSY1c magnet current (amp) : 49.6221
    Radiator 5V Linear Supply : 0.00488401
    Radiator Encoder : 0
    Right Arm Arm Collimator : 0.865576
    Left Arm Arm Collimator : 0.868701
    HacR_HPE1313A:0_Ch58 : -0.512207
    HacR_HPE1313A:0_Ch55 : 23.7305
    HacR_HPE1313A:0_Ch54 : -0.777832
    HacR_alignROLL : -0.245339
    HacR_alignPITCH : 0.0757577
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.125
    HacL_HPE1313A:0_Ch55 : 24.5605
    HacL_HPE1313A:0_Ch54 : -0.153809
    HacL_alignROLL : 0.0455629
    HacL_alignPITCH : 0.161596
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 20
    Right Arm Angle Vernier : -34
    Right Arm Scattering Angle : 20.0018
    Left Arm Angle Floor Angle : 20
    Left Arm Angle Vernier : 31.2
    Left Arm Scattering Angle : 20.005
    Wien angle :
    Helicity Mode ON/OFF Random/Toggle :
    Wien BDL :
    Wien field :
    Laser attenuation Hall A :
    Laser power Hall A : CAC: UDP send error = "Connection refused" CAC: UDP send error = "Connection refused" CAC: UDP send error = "Connection refused"
    Half-wave plate (off=out) :
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.769
    Survey Y offset bpmB : -1