Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 04:20:56 on June 6, 2001
Entry number 62059
keyword=Start_Run_20391,Run_type=other,beam_energy=1.197,beam_halfwaveplate=in,beam_polarization=80.0,beam_raster=off,comment_text=N2 reference, 22 psig,daq_mode=one HRS daq,leftarm_p=1191.4,leftarm_theta=20,rightarm_p=1191.4,rightarm_theta=20,target_halfwaveplate=out,target_name=N2,target_polarization=45.0,target_type=Reference Cell
Beginning-of-run EPICS data for Run Number 20391 at Wed Jun 6 04:20:35 EDT 2001
; RIGHT SPECTROMETER
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string.
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 to measure efficiency
;
ps1=2,ps2=2,ps8=65535
Right Arm Q1 power supply current : 895.825
Right Arm Q1 momentum : 1.19136
Right Arm Q1 gauss meter : -0.022363
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 512.784
Right Arm Q2 momentum : 1.1915
Right Arm Q2 gauss meter : 0.2697
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 408.856
Right Arm D1 momentum : 1.1914
Right Arm D1 NMR : 0.442114
Right Arm Q3 power supply current : 474.139
Right Arm Q3 momentum : 1.19158
Right Arm Q3 gauss meter : 0.2124
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 896.245
Left Arm Q1 momentum :
Left Arm Q1 gauss meter : -0.07578
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 512.932
Left Arm Q2 momentum : 1.1912
Left Arm Q2 gauss meter : 0.2709
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 398.559
Left Arm D1 momentum : 1.19139
Left Arm D1 NMR : 0.441035
Left Arm Q3 power supply current :
Left Arm Q3 momentum : 1.19165
Left Arm Q3 gauss meter : -0.2369
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0238148
Current on Unser monitor : 6.22679
Current on Upstream bcm : 0.0247372
Current on Downstream bcm : 0.0228924
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) :
Beam energy : 1197.33
MBSY1c magnet current (amp) : 49.6221
Radiator 5V Linear Supply : 0.002442
Radiator Encoder : 0
Right Arm Arm Collimator : 0.865674
Left Arm Arm Collimator : 0.868652
HacR_HPE1313A:0_Ch58 : -0.51123
HacR_HPE1313A:0_Ch55 : 23.6816
HacR_HPE1313A:0_Ch54 : -0.778809
HacR_alignROLL : -0.246009
HacR_alignPITCH : 0.0764548
HacR_alignHPT : -0
HacL_HPE1313A:0_Ch58 :
HacL_HPE1313A:0_Ch55 : 24.6094
HacL_HPE1313A:0_Ch54 : -0.154297
HacL_alignROLL : 0.0456361
HacL_alignPITCH : 0.161671
HacL_alignHPT : -0
Right Arm Angle Floor Angle : 20
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 20.0018
Left Arm Angle Floor Angle : 20
Left Arm Angle Vernier : 31.2
Left Arm Scattering Angle : 20.005
Wien angle : CAC: UDP send error = "Connection refused"
Helicity Mode ON/OFF Random/Toggle :
Wien BDL :
Wien field :
Laser attenuation Hall A : CAC: UDP send error = "Connection refused"
Laser power Hall A :
Half-wave plate (off=out) :
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.769
Survey Y offset bpmB : -1