    Log entry time 06:25:29 on June 6, 2001

    Entry number 62078

    keyword=Start_Run_20395,Run_type=other,beam_energy=1.197,beam_halfwaveplate=in,beam_polarization=80.0,beam_raster=off,comment_text=He4 reference, 23 psig,daq_mode=one HRS daq,leftarm_p=1175.0,leftarm_theta=20,rightarm_p=1175.0,rightarm_theta=20,target_halfwaveplate=out,target_name=He4,target_polarization=45.0,target_type=Reference Cell
    Beginning-of-run EPICS data for Run Number 20395 at Wed Jun 6 06:25:08 EDT 2001
    ; RIGHT SPECTROMETER
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string.
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 to measure efficiency
    ;
    ps1=3,ps2=3,ps8=65535
    
    
     Right Arm Q1 power supply current : 883.575
    Right Arm Q1 momentum : 1.17507
    Right Arm Q1 gauss meter : -0.022059
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 505.767
    Right Arm Q2 momentum : 1.1752
    Right Arm Q2 gauss meter : 0.2658
    Right Arm Q2 power supply polarity : 0
    Right Arm D1 power supply current : 402.895
    Right Arm D1 momentum : 1.175
    Right Arm D1 NMR : 0.436029
    Right Arm Q3 power supply current : 467.554
    Right Arm Q3 momentum : 1.17503
    Right Arm Q3 gauss meter : 0.2095
    Right Arm Q3 power supply polarity : 1
    Left Arm Q1 power supply current : 883.96
    Left Arm Q1 momentum : 1.17496
    Left Arm Q1 gauss meter : -0.07472
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 505.851
    Left Arm Q2 momentum : 1.17476
    Left Arm Q2 gauss meter : 0.2672
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 393.009
    Left Arm D1 momentum : 1.175
    Left Arm D1 NMR : 0.434974
    Left Arm Q3 power supply current : 467.74
    Left Arm Q3 momentum : 1.17488
    Left Arm Q3 gauss meter : -0.2337
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 7.40275
    Current on Unser monitor : 12.5019
    Current on Upstream bcm : 7.44254
    Current on Downstream bcm : 7.36296
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) :
    Beam energy : 1197.33
    MBSY1c magnet current (amp) : 49.6221
    Radiator 5V Linear Supply : 0
    Radiator Encoder : 0
    Right Arm Arm Collimator : 0.865625
    Left Arm Arm Collimator : 0.86875
    HacR_HPE1313A:0_Ch58 : -0.511719
    HacR_HPE1313A:0_Ch55 : 23.6816
    HacR_HPE1313A:0_Ch54 : -0.77832
    HacR_alignROLL : -0.245891
    HacR_alignPITCH : 0.077038
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.125
    HacL_HPE1313A:0_Ch55 :
    HacL_HPE1313A:0_Ch54 : -0.154785
    HacL_alignROLL : 0.0455629
    HacL_alignPITCH : 0.161596
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 20
    Right Arm Angle Vernier : -34
    Right Arm Scattering Angle : 20.0018
    Left Arm Angle Floor Angle : 20
    Left Arm Angle Vernier : 31.2
    Left Arm Scattering Angle : 20.005
    Wien angle :
    Helicity Mode ON/OFF Random/Toggle :
    Wien BDL :
    Wien field :
    Laser attenuation Hall A : CAC: UDP send error = "Connection refused"
    Laser power Hall A :
    Half-wave plate (off=out) :
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.769
    Survey Y offset bpmB : -1