• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 20:30:48 on June 6, 2001

    Entry number 62182

    keyword=Start_Run_20412,Run_type=other,beam_energy=1.197,beam_halfwaveplate=in,beam_polarization=80.0,beam_raster=on,comment_text=False asymmetry study, parity run 619,daq_mode=one HRS daq,leftarm_p=1112.0,leftarm_theta=20,rightarm_p=1112.0,rightarm_theta=20,target_halfwaveplate=out,target_name=Gore,target_polarization=36,target_type=BeO Carbon foils
    Beginning-of-run EPICS data for Run Number 20412 at Wed Jun 6 20:30:30 EDT 2001
    ; RIGHT SPECTROMETER
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string.
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 to measure efficiency
    ;
    ps1=50,ps2=50,ps8=65535
    
    
     Right Arm Q1 power supply current : 836.115
    Right Arm Q1 momentum : 1.11195
    Right Arm Q1 gauss meter : -0.020896
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 478.654
    Right Arm Q2 momentum : 1.1122
    Right Arm Q2 gauss meter : 0.2516
    Right Arm Q2 power supply polarity : 0
    Right Arm D1 power supply current : 380.626
    Right Arm D1 momentum : 1.112
    Right Arm D1 NMR : 0.41265
    Right Arm Q3 power supply current : 442.447
    Right Arm Q3 momentum : 1.11193
    Right Arm Q3 gauss meter : 0.1982
    Right Arm Q3 power supply polarity : 1
    Left Arm Q1 power supply current : 836.64
    Left Arm Q1 momentum : 1.11206
    Left Arm Q1 gauss meter : -0.07075
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 478.936
    Left Arm Q2 momentum : 1.11225
    Left Arm Q2 gauss meter : 0.2529
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 371.505
    Left Arm D1 momentum : 1.112
    Left Arm D1 NMR : 0.411677
    Left Arm Q3 power supply current : 442.77
    Left Arm Q3 momentum : 1.11216
    Left Arm Q3 gauss meter : -0.2211
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 15.1793
    Current on Unser monitor : 21.0841
    Current on Upstream bcm : 15.0569
    Current on Downstream bcm : 15.2828
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) :
    Beam energy : 1197.33
    MBSY1c magnet current (amp) : 49.6221
    Radiator 5V Linear Supply : 0.00488401
    Radiator Encoder : 0
    Right Arm Arm Collimator : 0.865625
    Left Arm Arm Collimator : 0.868701
    HacR_HPE1313A:0_Ch58 : -0.510742
    HacR_HPE1313A:0_Ch55 : 23.6816
    HacR_HPE1313A:0_Ch54 : -0.776855
    HacR_alignROLL : -0.244846
    HacR_alignPITCH : 0.076656
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.124512
    HacL_HPE1313A:0_Ch55 : 24.6582
    HacL_HPE1313A:0_Ch54 : -0.154785
    HacL_alignROLL : 0.0451941
    HacL_alignPITCH : 0.162107
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 20
    Right Arm Angle Vernier : -34
    Right Arm Scattering Angle : 20.0018
    Left Arm Angle Floor Angle : 20
    Left Arm Angle Vernier : 31.2
    Left Arm Scattering Angle : 20.005
    Wien angle :
    Helicity Mode ON/OFF Random/Toggle :
    Wien BDL :
    Wien field :
    Laser attenuation Hall A :
    Laser power Hall A : CAC: UDP send error = "Connection refused" CAC: UDP send error = "Connection refused"
    Half-wave plate (off=out) :
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.769
    Survey Y offset bpmB : -1