• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 21:41:43 on June 6, 2001

    Entry number 62224

    keyword=End_of_Run_20420
    ****************************
     Run Number: 20420
     End of Run Comment:
    Run_type=other,beam_energy=1.197,beam_halfwaveplate=in,beam_polarization=80.0,beam_raster=on,comment_text=False asymmetry study, parity run 627,daq_mode=one HRS daq,leftarm_p=1112.0,leftarm_theta=20,rightarm_p=1112.0,rightarm_theta=20,target_halfwaveplate=out,target_name=Gore,target_polarization=36,target_type=BeO Carbon foils
     
    
    PRESCALE FACTORS:ps1=15   ps2=15   ps8=65535   
    
    EVENTS[0]: 868315      [+]: 429162      [-]: 429111      
    TIME  [0]:   3.1 mins  [+]:   1.5 mins  [-]:   1.5 mins  
    LIVE  [0]: 145.76%     [+]: 145.76%     [-]: 145.77%     
    
    TRIGGER RATES:
    T1[0] [PRES/REAL]:3180.1/47701.3 Hz   T2[0] [PRES/REAL]:71.0/1065.3 Hz   T8[0] [PRES/REAL]: 0.0/1024.0 Hz   
    T1[+] [PRES/REAL]:3180.3/47704.2 Hz   T2[+] [PRES/REAL]:71.0/1064.8 Hz   T8[+] [PRES/REAL]: 0.0/1024.0 Hz   
    T1[-] [PRES/REAL]:3178.6/47678.7 Hz   T2[-] [PRES/REAL]:71.0/1065.5 Hz   T8[-] [PRES/REAL]: 0.0/1024.0 Hz   
    
    APPROXIMATE CHARGE ASYMMETRIES
    BCM u1 :    308.9 ppm     BCM u3 :      287 ppm     BCM u10:      285 ppm     
    BCM d1 :      311 ppm     BCM d3 :    276.5 ppm     BCM d10:    283.3 ppm     
    
    APPROXIMATE BCM CHARGES
    BCM u1 [0]:0.002677       BCM u3 [0]:0.002688       BCM u10[0]:0.002696       
    BCM u1 [+]:0.001323       BCM u3 [+]:0.001329       BCM u10[+]:0.001332       
    BCM u1 [-]:0.001323       BCM u3 [-]:0.001329       BCM u10[-]:0.001332       
    
    BCM d1 [0]:0.002731       BCM d3 [0]:0.002737       BCM d10[0]:0.002741       
    BCM d1 [+]:0.00135        BCM d3 [+]:0.001353       BCM d10[+]:0.001355       
    BCM d1 [-]:0.001349       BCM d3 [-]:0.001353       BCM d10[-]:0.001355       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 20420 at Wed Jun 6 21:41:03 EDT 2001
    Right Arm D1 momentum : 1.112
    Right Arm arm angle : 20.0018
    Left Arm D1 momentum : 1.112
    Left Arm arm angle : 20.005
    Tiefenbach Hall A energy :
    Right Arm arm mispointing (HPT) : -0
    Left Arm arm mispointing (HPT) : -0
    Right Arm Q1 power supply current : 836.045
    Right Arm Q1 momentum : 1.11186
    Right Arm Q1 gauss meter : -0.02088
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 478.346
    Right Arm Q2 momentum : 1.11148
    Right Arm Q2 gauss meter : 0.2516
    Right Arm Q2 power supply polarity : 0
    Right Arm D1 power supply current : 380.63
    Right Arm D1 momentum : 1.112
    Right Arm D1 NMR : 0.41265
    Right Arm Q3 power supply current : 442.449
    Right Arm Q3 momentum : 1.11194
    Right Arm Q3 gauss meter : 0.1982
    Right Arm Q3 power supply polarity : 1
    Left Arm Q1 power supply current : 836.71
    Left Arm Q1 momentum : 1.11216
    Left Arm Q1 gauss meter : -0.07076
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 478.84
    Left Arm Q2 momentum : 1.11203
    Left Arm Q2 gauss meter : 0.2529
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 371.505
    Left Arm D1 momentum : 1.112
    Left Arm D1 NMR : 0.411678
    Left Arm Q3 power supply current : 442.688
    Left Arm Q3 momentum : 1.11195
    Left Arm Q3 gauss meter : -0.2211
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 14.7158
    Current on Unser monitor : 19.3319
    Current on Upstream bcm : 14.6169
    Current on Downstream bcm : 14.8146
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) :
    MBSY1c Hall A Beam energy : 1197.33
    MBSY1c magnet current (amp) : 49.6221
    MBSY1c Bdl : 298794
    MBSY3c Hall C Beam energy : 21.1371
    Tiefenbach Hall A energy :
    Tiefenbach Hall C energy :
    Delta(E)/E width (MV_AI_DXWID) :
    IPM1C12.XPOS :
    IPM1H04A.XPOS : -3.1576
    IPM1H04A.YPOS : -3.01159
    IPM1H04B.XPOS : -3.16643
    IPM1H04B.YPOS : -3.02536
    Right Arm Arm Collimator : 0.865674
    Left Arm Arm Collimator : 0.868701
    HacR_HPE1313A:0_Ch58 : -0.51123
    HacR_HPE1313A:0_Ch55 : 23.7305
    HacR_HPE1313A:0_Ch54 : -0.777344
    HacR_alignROLL : -0.244787
    HacR_alignPITCH : 0.0762739
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.124512
    HacL_HPE1313A:0_Ch55 : 24.6094
    HacL_HPE1313A:0_Ch54 : -0.154785
    HacL_alignROLL : 0.0452673
    HacL_alignPITCH : 0.161745
    HacL_alignHPT : -0
    Right Arm Arm Collimator : 0.865576
    Left Arm Arm Collimator : 0.86875
    Wien angle :
    Helicity Mode ON/OFF Random/Toggle :
    Wien BDL :
    Wien field :
    Laser attenuation Hall A :
    Laser power Hall A :
    Half-wave plate (off=out) :
    Polarized 3He Target RTD #1 : 50.2051
    Polarized 3He Target RTD #2 : 51.0059
    Polarized 3He Target RTD #3 : !!WARNING!! The executable "caRepeater" couldnt be located because of errno = "No such file or directory" You may need to modify your PATH environment variable. Creating CA repeater with fork() system call. Repeater will inherit parents process name and resources. Duplicate resource consumption may occur. 54.5801
    Polarized 3He Target RTD #4 : 52.5
    Polarized 3He Target RTD #5 : 52.2656
    Polarized 3He Target RTD #6 : 204.316
    Polarized 3He Target RTD #7 : 194.004
    Polarized 3He Ref. Cell RTD #8 : 50.2344
    Polarized 3He Ref. Cell RTD #9 : 50.1953
    Polarized 3He Ref. Cell RTD #10 : 50.2539
    Polarized 3He Target Ref. Cell Gas Pres. : 103.814
    Polarized 3He Target Ref. Cell Sys.Vac. : 1112.66
    Polarized 3He Target Cooling Jet : 29.9121
    Polarized 3He Target OVEN RTD : 179.9
    Polarized 3He Target OVEN SP1 SET : 180
    Polarized 3He Target OVEN SP1 : 180
    Polarized 3He Target OVEN AL1 SET : 150
    Polarized 3He Target OVEN AL1 : 150
    Polarized 3He Target OVEN AL1 STATUS : enabled
    Polarized 3He Target Half-Wave Plate DIST:
    Polarized 3He Target Half-Wave Plate STAT: NO_ALARM
    Polarized 3He Target Position (PA) : 70.2095
    Polarized 3He Target Position (POS) : BeO+12C Foils
    Polarized 3He Target Position (DA) : 70.2095
    Polarized 3He Target Position (SS9) : Axis is OK
    Polarized 3He Target Position (SA10) : 0
    Polarized 3He Target Position (SA9) : 0
    Polarized 3He Laser#1 State : 0
    Polarized 3He Laser#1 Current : 38
    Polarized 3He Laser#1 Temperature : 14
    Polarized 3He Laser#2 State : 0
    Polarized 3He Laser#2 Current : 37
    Polarized 3He Laser#2 Temperature : 23
    Polarized 3He Laser#3 State : 0
    Polarized 3He Laser#3 Current : 40
    Polarized 3He Laser#3 Temperature : 26.4
    Polarized 3He Laser#4 State : 2
    Polarized 3He Laser#4 Current : 40
    Polarized 3He Laser#4 Temperature : 15
    Polarized 3He Laser#5 State : 13
    Polarized 3He Laser#5 Current : 0
    Polarized 3He Laser#5 Temperature : 0
    Polarized 3He Laser#6 State : 2
    Polarized 3He Laser#6 Current : 40
    Polarized 3He Laser#6 Temperature : 14
    Polarized 3He Laser#7 State : 2
    Polarized 3He Laser#7 Current : 36
    Polarized 3He Laser#7 Temperature : 18.5
    Polarized 3He Coil Current Longitudinal :
    Polarized 3He Coil Current Transverse :