• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name jpchen

    Log entry time 00:06:42 on June 7,2001

    Entry number 62282

    keyword=Swing Shift summary

    16:00 Beam was centered on BPMB at -2.75mm, -2.75mm, but not
    on BPMA. The previous shift asked for tuning, but MCC is busy with
    figure out why can not go higher than 8 uA. We took some 12C data
    to for checking.
    17:00 MCC decided to change laser to diode.
    18:00-18:40 started tuning beam back, checking BeO, centered at -3mm on all BPM(A, B/ X,Y). Checked raster, adjusted to 4mm.
    18:40-19:00 Tried to start charge asymmetry test, MCC asked to take beam away to
    calibrate BCMs so they can deliver 15 uA.
    19:00 MCC got us 15 uA. started charge asymmetry test (Joe and Antonin)
    and also started data taking for C12 fale asymmetry run.
    19:20 After 15 minutes beam, RF dropped off.
    20:30 beam back. Started charge asymmetry and 12C false asymmetry data taking.
    Problem with right arm deadtime (DAQ).
    22:30 Completed cahrge asymmetry and 12C false asymmety study data taking.
    23:00 Completed mini current calibration.
    24:00 still doing N2 false asymmetry study.