User name a-onl
Log entry time 03:55:46 on June 8, 2001
Entry number 62417
keyword=Start_Run_20453,Run_type=other,beam_energy=1.197,beam_halfwaveplate=in,beam_polarization=80.0,beam_raster=on,comment_text=ref cell with 3He at 110 psig False Asymmetry test,daq_mode=one HRS daq,leftarm_p=1112.0,leftarm_theta=20,rightarm_p=1112.0,rightarm_theta=20,target_halfwaveplate=out,target_name=Gore,target_polarization=36,target_type=Reference Cell
Beginning-of-run EPICS data for Run Number 20453 at Fri Jun 8 03:55:29 EDT 2001
; RIGHT SPECTROMETER
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string.
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 to measure efficiency
;
ps1=7,ps2=7,ps8=65535
Right Arm Q1 power supply current : 836.22
Right Arm Q1 momentum : 1.11209
Right Arm Q1 gauss meter : -0.020899
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 478.557
Right Arm Q2 momentum : 1.11197
Right Arm Q2 gauss meter : 0.2516
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 380.56
Right Arm D1 momentum : 1.112
Right Arm D1 NMR : 0.41265
Right Arm Q3 power supply current : 442.437
Right Arm Q3 momentum : 1.11191
Right Arm Q3 gauss meter : 0.19819
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 836.535
Left Arm Q1 momentum : 1.11192
Left Arm Q1 gauss meter : -0.07076
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 478.766
Left Arm Q2 momentum : 1.11186
Left Arm Q2 gauss meter : 0.2529
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 371.475
Left Arm D1 momentum : 1.112
Left Arm D1 NMR : 0.411676
Left Arm Q3 power supply current : 442.925
Left Arm Q3 momentum : 1.11254
Left Arm Q3 gauss meter : -0.2212
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 9.61791
Current on Unser monitor : 13.9796
Current on Upstream bcm : 9.55447
Current on Downstream bcm : 9.68135
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : CAC: UDP send error = "Connection refused"
Beam energy : 1197.33
MBSY1c magnet current (amp) : 49.6221
Radiator 5V Linear Supply : 0.002442
Radiator Encoder : 0
Right Arm Arm Collimator : 0.865576
Left Arm Arm Collimator : 0.86875
HacR_HPE1313A:0_Ch58 : -0.510254
HacR_HPE1313A:0_Ch55 : 23.6816
HacR_HPE1313A:0_Ch54 : -0.776855
HacR_alignROLL : -0.244905
HacR_alignPITCH : 0.077038
HacR_alignHPT : -0
HacL_HPE1313A:0_Ch58 : -0.125488
HacL_HPE1313A:0_Ch55 : 24.6582
HacL_HPE1313A:0_Ch54 : -0.154297
HacL_alignROLL : 0.0452673
HacL_alignPITCH : 0.161308
HacL_alignHPT : -0
Right Arm Angle Floor Angle : 20
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 20.0018
Left Arm Angle Floor Angle : 20
Left Arm Angle Vernier : 31.2
Left Arm Scattering Angle : 20.005
Wien angle :
Helicity Mode ON/OFF Random/Toggle :
Wien BDL :
Wien field :
Laser attenuation Hall A :
Laser power Hall A : CAC: UDP send error = "Connection refused"
Half-wave plate (off=out) :
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.769
Survey Y offset bpmB : -1