    User name a-onl

    Log entry time 04:21:18 on June 8, 2001

    Entry number 62422

    keyword=Start_Run_20454,Run_type=other,beam_energy=1.197,beam_halfwaveplate=in,beam_polarization=80.0,beam_raster=on,comment_text=ref cell with 3He at 110 psig False Asymmetry test,daq_mode=one HRS daq,leftarm_p=1112.0,leftarm_theta=20,rightarm_p=1112.0,rightarm_theta=20,target_halfwaveplate=out,target_name=Gore,target_polarization=40,target_type=Reference Cell
    Beginning-of-run EPICS data for Run Number 20454 at Fri Jun 8 04:21:01 EDT 2001
    ; RIGHT SPECTROMETER
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string.
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 to measure efficiency
    ;
    ps1=4,ps2=4,ps8=65535
    
    
     Right Arm Q1 power supply current : 836.15
    Right Arm Q1 momentum : 1.112
    Right Arm Q1 gauss meter : -0.020892
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 478.437
    Right Arm Q2 momentum : 1.11169
    Right Arm Q2 gauss meter : 0.2516
    Right Arm Q2 power supply polarity : 0
    Right Arm D1 power supply current : 380.56
    Right Arm D1 momentum : 1.112
    Right Arm D1 NMR : 0.41265
    Right Arm Q3 power supply current : 442.529
    Right Arm Q3 momentum : 1.11214
    Right Arm Q3 gauss meter : 0.19828
    Right Arm Q3 power supply polarity : 1
    Left Arm Q1 power supply current : 836.64
    Left Arm Q1 momentum : 1.11206
    Left Arm Q1 gauss meter : -0.07076
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 478.756
    Left Arm Q2 momentum : 1.11183
    Left Arm Q2 gauss meter : 0.2529
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 371.475
    Left Arm D1 momentum : 1.112
    Left Arm D1 NMR : 0.411676
    Left Arm Q3 power supply current : 442.671
    Left Arm Q3 momentum : 1.11191
    Left Arm Q3 gauss meter : -0.2211
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 9.58194
    Current on Unser monitor : 14.8133
    Current on Upstream bcm : 9.48069
    Current on Downstream bcm : 9.6832
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) :
    Beam energy : 1197.33
    MBSY1c magnet current (amp) : 49.6221
    Radiator 5V Linear Supply : 0.00732601
    Radiator Encoder : 0
    Right Arm Arm Collimator : 0.865625
    Left Arm Arm Collimator : 0.868652
    HacR_HPE1313A:0_Ch58 : -0.509766
    HacR_HPE1313A:0_Ch55 : 23.7305
    HacR_HPE1313A:0_Ch54 : -0.776855
    HacR_alignROLL : -0.244905
    HacR_alignPITCH : 0.077038
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.125
    HacL_HPE1313A:0_Ch55 : 24.6582
    HacL_HPE1313A:0_Ch54 : -0.154785
    HacL_alignROLL : 0.0452673
    HacL_alignPITCH : 0.161745
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 20
    Right Arm Angle Vernier : -34
    Right Arm Scattering Angle : 20.0018
    Left Arm Angle Floor Angle : 20
    Left Arm Angle Vernier : 31.2
    Left Arm Scattering Angle : 20.005
    Wien angle :
    Helicity Mode ON/OFF Random/Toggle :
    Wien BDL :
    Wien field :
    Laser attenuation Hall A :
    Laser power Hall A : CAC: UDP send error = "Connection refused"
    Half-wave plate (off=out) :
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.769
    Survey Y offset bpmB : -1