• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name Armstrong

    Log entry time 21:09:52 on June26,2001

    Entry number 64705

    keyword=charge asymmetry over time


    While bored and waiting for beam, I looked at the run-by-run charge asymmetry
    (from the parity DAQ analysis, using the chkfeedback script) for the last week's
    worth of data, i.e. starting at Parity run 857, when the Parity DAQ was turned back
    on. The automatic feedback was on through almost all of this.

    - The average asymmetry was -13 ppm (not bad)
    - The standard deviation was 192 ppm (not so good)

    The history is shown below; the error bars are mostly smaller than the
    size of the data points. Most of the fluctuation appears to be related to the
    large beam-current-correlated oscillations in the asymmetry that we have
    noted before.




    FIGURE 1