• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 19:55:21 on June 27, 2001

    Entry number 64810

    keyword=Start_Run_20820,Run_type=production,beam_energy=5.7265,beam_halfwaveplate=in,beam_polarization=82.,beam_raster=on,comment_text=,daq_mode=both HRS daq,leftarm_p=1455,leftarm_theta=45,rightarm_p=1455,rightarm_theta=45,target_halfwaveplate=out,target_name=Gore,target_polarization=40.0,target_type=Polarized He-3 270deg
    Beginning-of-run EPICS data for Run Number 20820 at Wed Jun 27 19:54:58 EDT 2001
    ; RIGHT SPECTROMETER
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string.
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 to measure efficiency
    ;
    ps1=1,ps2=1,ps8=65535
    
    
     Right Arm Q1 power supply current : 1093.99
    Right Arm Q1 momentum : 1.45491
    Right Arm Q1 gauss meter : -0.027275
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 626.13
    Right Arm Q2 momentum : 1.45487
    Right Arm Q2 gauss meter : 0.3292
    Right Arm Q2 power supply polarity : 0
    Right Arm D1 power supply current : 500.048
    Right Arm D1 momentum : 1.455
    Right Arm D1 NMR : 0.539933
    Right Arm Q3 power supply current : 578.874
    Right Arm Q3 momentum : 1.45479
    Right Arm Q3 gauss meter : 0.2596
    Right Arm Q3 power supply polarity : 1
    Left Arm Q1 power supply current : 1094.66
    Left Arm Q1 momentum : 1.45502
    Left Arm Q1 gauss meter : -0.09254
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 626.458
    Left Arm Q2 momentum : 1.45485
    Left Arm Q2 gauss meter :
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 487.676
    Left Arm D1 momentum : 1.455
    Left Arm D1 NMR : 0.538522
    Left Arm Q3 power supply current : 579.217
    Left Arm Q3 momentum : 1.45488
    Left Arm Q3 gauss meter : -0.2894
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities :
    Current on Unser monitor :
    Current on Upstream bcm :
    Current on Downstream bcm :
    Upstream Cavity Coefficient :
    Downstream Cavity Coefficient :
    Current on IBC0L02 (source) : CAC: UDP send error = "Connection refused"
    Beam energy : 5738.42
    MBSY1c magnet current (amp) : 239.881
    Radiator 5V Linear Supply : 0.00488401
    Radiator Encoder : 0
    Right Arm Arm Collimator : 0.865381
    Left Arm Arm Collimator : 0.868701
    HacR_HPE1313A:0_Ch58 : -0.505859
    HacR_HPE1313A:0_Ch55 : 25.5371
    HacR_HPE1313A:0_Ch54 : -0.873047
    HacR_alignROLL : -0.339368
    HacR_alignPITCH : 0.0845981
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.246582
    HacL_HPE1313A:0_Ch55 : 26.2207
    HacL_HPE1313A:0_Ch54 : -0.34082
    HacL_alignROLL : -0.121359
    HacL_alignPITCH : 0.0543948
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 45
    Right Arm Angle Vernier : -34
    Right Arm Scattering Angle : 45.0002
    Left Arm Angle Floor Angle : 45
    Left Arm Angle Vernier : 31
    Left Arm Scattering Angle : 45.0068
    Wien angle :
    Helicity Mode ON/OFF Random/Toggle :
    Wien BDL :
    Wien field :
    Laser attenuation Hall A : CAC: UDP send error = "Connection refused"
    Laser power Hall A :
    Half-wave plate (off=out) :
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.769
    Survey Y offset bpmB : -1