Log entry time 19:18:12 on June 30, 2001
Entry number 65158
keyword=Start_Run_20872,Run_type=production,beam_energy=5.7265,beam_halfwaveplate=in,beam_polarization=82.,beam_raster=on,comment_text=,daq_mode=both HRS daq,leftarm_p=1455,leftarm_theta=45,rightarm_p=1455,rightarm_theta=45,target_halfwaveplate=in,target_name=Gore,target_polarization=37.5,target_type=Polarized He-3 180deg
Beginning-of-run EPICS data for Run Number 20872 at Sat Jun 30 19:17:47 EDT 2001
; RIGHT SPECTROMETER
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string.
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep eno
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string.
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 to measure efficiency
;
ps1=1,ps2=1,ps8=65535
Right Arm Q1 power supply current : 1093.96
Right Arm Q1 momentum : 1.45486
Right Arm Q1 gauss meter : -0.027283
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 626.31
Right Arm Q2 momentum : 1.45529
Right Arm Q2 gauss meter : 0.3291
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 499.893
Right Arm D1 momentum : 1.455
Right Arm D1 NMR : 0.539933
Right Arm Q3 power supply current : 578.957
Right Arm Q3 momentum : 1.455
Right Arm Q3 gauss meter : 0.2596
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1094.59
Left Arm Q1 momentum : 1.45493
Left Arm Q1 gauss meter : -0.09253
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 626.468
Left Arm Q2 momentum : 1.45487
Left Arm Q2 gauss meter : 0.3307
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 487.765
Left Arm D1 momentum : 1.455
Left Arm D1 NMR : 0.538521
Left Arm Q3 power supply current : 579.261
Left Arm Q3 momentum :
Left Arm Q3 gauss meter : -0.2895
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 10.4698
Current on Unser monitor : 14.7715
Current on Upstream bcm : 10.4085
Current on Downstream bcm : 10.5466
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : CAC: UDP send error = "Connection refused"
Beam energy : 5738.42
MBSY1c magnet current (amp) : 239.881
Radiator 5V Linear Supply : 0.002442
Radiator Encoder : 0
Right Arm Arm Collimator : 0.865381
Left Arm Arm Collimator : 0.868701
HacR_HPE1313A:0_Ch58 : -0.506348
HacR_HPE1313A:0_Ch55 : 25.7324
HacR_HPE1313A:0_Ch54 : -0.872559
HacR_alignROLL : -0.339255
HacR_alignPITCH : 0.0842829
HacR_alignHPT : -0
HacL_HPE1313A:0_Ch58 : -0.247559
HacL_HPE1313A:0_Ch55 : 26.4648
HacL_HPE1313A:0_Ch54 : -0.339844
HacL_alignROLL : -0.119686
HacL_alignPITCH : 0.0547542
HacL_alignHPT : -0
Right Arm Angle Floor Angle : 45
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 45.0002
Left Arm Angle Floor Angle : 45
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 45.0067
Wien angle :
Helicity Mode ON/OFF Random/Toggle : CAC: UDP send error = "Connection refused"
Wien BDL :
Wien field : CAC: UDP send error = "Connection refused"
Laser attenuation Hall A : CAC: UDP send error = "Connection refused"
Laser power Hall A :
Half-wave plate (off=out) : CAC: UDP send error = "Connection refused"
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.769
Survey Y offset bpmB : -1