• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name X. Zheng

    Log entry time 11:01:29 on July 1,2001

    Entry number 65261

    keyword=Target - EPR - 37.6%

    10:51am, EPR with beam off, laser #6 on.
    target position: pol 3he cell

    1st order fit:
    down: freq. shift = -45.23 KHz +/- 1.55 KHz, P = -37.56%+/- 1.29%
    up: freq. shift = 44.06 KHz +/- 1.59 KHz, P = 36.59%+/- 1.32%

    0th order fit:
    down: freq. shift = -45.35 KHz +/- 1.57 KHz, P = -37.66%+/- 1.30%
    up: freq. shift = 44.79 KHz +/- 1.61 KHz, P = 37.20%+/- 1.34%

    Before measurment I lowered rel gain and abs. gain by about 0.1 turn, which should
    fix the problem Kevin had this morning. During measurment I found the sweep is quite slow so in the end I change the abs. gain back. The current setting (low rel. gain) can keep the noise level low but it may cause sweeps to fail.