• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 12:29:41 on July 9, 2001

    Entry number 65711

    keyword=Start_Run_20957,Run_type=cosmics,beam_energy=5.7265,beam_halfwaveplate=out,beam_polarization=82.,beam_raster=on,comment_text=cosmic,daq_mode=one HRS daq,leftarm_p=0,leftarm_theta=45,rightarm_p=0,rightarm_theta=45,target_halfwaveplate=out,target_name=,target_polarization=37,target_type=Empty
    Beginning-of-run EPICS data for Run Number 20957 at Mon Jul 9 12:29:24 EDT 2001
    ; RIGHT SPECTROMETER
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string.
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 to measure efficiency
    ;
    ps1=1,ps2=1,ps8=65535
    
    
     Right Arm Q1 power supply current : 0
    Right Arm Q1 momentum : 0
    Right Arm Q1 gauss meter : 0.0001016
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 0.413773
    Right Arm Q2 momentum : 0.000961441
    Right Arm Q2 gauss meter : -0.0002362
    Right Arm Q2 power supply polarity : 1
    Right Arm D1 power supply current : 1.99095
    Right Arm D1 momentum : 0
    Right Arm D1 NMR : 0.474141
    Right Arm Q3 power supply current : 0.183894
    Right Arm Q3 momentum :
    Right Arm Q3 gauss meter : -0.0001962
    Right Arm Q3 power supply polarity : 0
    Left Arm Q1 power supply current : 0
    Left Arm Q1 momentum : 0
    Left Arm Q1 gauss meter : 0.0003922
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 0.323616
    Left Arm Q2 momentum : 0.000751547
    Left Arm Q2 gauss meter : 0.0002201
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1.07371
    Left Arm D1 momentum : 0
    Left Arm D1 NMR : 0.289397
    Left Arm Q3 power supply current : 2.02671
    Left Arm Q3 momentum : 0.00509072
    Left Arm Q3 gauss meter : -4.62e-05
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 0.02319
    Current on Unser monitor : 4.07163
    Current on Upstream bcm : 0.0252319
    Current on Downstream bcm : 0.0211481
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) :
    Beam energy : 5738.42
    MBSY1c magnet current (amp) : 0.0377197
    Radiator 5V Linear Supply : 0.00488401
    Radiator Encoder : 0
    Right Arm Arm Collimator : 0.865332
    Left Arm Arm Collimator : 0.868848
    HacR_HPE1313A:0_Ch58 : -0.502441
    HacR_HPE1313A:0_Ch55 : 25.8301
    HacR_HPE1313A:0_Ch54 : -0.860352
    HacR_alignROLL : -0.326247
    HacR_alignPITCH : 0.0876316
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.16748
    HacL_HPE1313A:0_Ch55 : 26.7578
    HacL_HPE1313A:0_Ch54 : -0.170898
    HacL_alignROLL : 0.0342597
    HacL_alignPITCH : 0.126905
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 45
    Right Arm Angle Vernier : -34
    Right Arm Scattering Angle : 45.0004
    Left Arm Angle Floor Angle : 45
    Left Arm Angle Vernier : 31
    Left Arm Scattering Angle : 45.0041
    Wien angle :
    Helicity Mode ON/OFF Random/Toggle :
    Wien BDL :
    Wien field :
    Laser attenuation Hall A :
    Laser power Hall A : CAC: UDP send error = "Connection refused" CAC: UDP send error = "Connection refused"
    Half-wave plate (off=out) :
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.769
    Survey Y offset bpmB : -1