Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 08:32:44 on July 11, 2001
Entry number 65777
keyword=Start_Run_20968,Run_type=cosmics,beam_energy=0,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=cosmic (no parity),daq_mode=one HRS daq,leftarm_p=0,leftarm_theta=45,rightarm_p=0,rightarm_theta=45,target_halfwaveplate=out,target_name=,target_polarization=37,target_type=Empty
Beginning-of-run EPICS data for Run Number 20968 at Wed Jul 11 08:32:25 EDT 2001
; RIGHT SPECTROMETER
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string.
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 to measure efficiency
;
ps1=1,ps2=1,ps8=65535
Right Arm Q1 power supply current : 9.345
Right Arm Q1 momentum : 0.0124279
Right Arm Q1 gauss meter : 0.000322
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 9.65261
Right Arm Q2 momentum : 0.0224288
Right Arm Q2 gauss meter : -0.005086
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 12.0065
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.381995
Right Arm Q3 power supply current : 9.30713
Right Arm Q3 momentum : 0.0231504
Right Arm Q3 gauss meter : -0.004264
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 9.345
Left Arm Q1 momentum : 0.0124214
Left Arm Q1 gauss meter : 0.0012674
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 7.99951
Left Arm Q2 momentum : 0.0185776
Left Arm Q2 gauss meter : -0.003818
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 11.0798
Left Arm D1 momentum : 0
Left Arm D1 NMR : 0.160838
Left Arm Q3 power supply current : 9.0886
Left Arm Q3 momentum : 0.0228289
Left Arm Q3 gauss meter : 0.003569
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0.0304709
Current on Unser monitor : 4.79959
Current on Upstream bcm : 0.0385584
Current on Downstream bcm : 0.0223833
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) :
Beam energy : 5738.42
MBSY1c magnet current (amp) : 239.881
Radiator 5V Linear Supply : 0.00488401
Radiator Encoder : 0
Right Arm Arm Collimator : 0.86543
Left Arm Arm Collimator : 0.868896
HacR_HPE1313A:0_Ch58 : -0.508301
HacR_HPE1313A:0_Ch55 : 24.5605
HacR_HPE1313A:0_Ch54 : -0.877441
HacR_alignROLL : -0.345056
HacR_alignPITCH : 0.0799752
HacR_alignHPT : -0
HacL_HPE1313A:0_Ch58 : -0.166016
HacL_HPE1313A:0_Ch55 : 25.3418
HacL_HPE1313A:0_Ch54 : -0.164551
HacL_alignROLL : 0.0374505
HacL_alignPITCH : 0.126081
HacL_alignHPT : -0
Right Arm Angle Floor Angle : 45
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 45.0001
Left Arm Angle Floor Angle : 45
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 45.004
Wien angle :
Helicity Mode ON/OFF Random/Toggle :
Wien BDL : CAC: UDP send error = "Connection refused" CAC: UDP send error = "Connection refused"
Wien field : CAC: UDP send error = "Connection refused" CAC: UDP send error = "Connection refused"
Laser attenuation Hall A : CAC: UDP send error = "Connection refused"
Laser power Hall A : CAC: UDP send error = "Connection refused" CAC: UDP send error = "Connection refused"
Half-wave plate (off=out) :
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.769
Survey Y offset bpmB : -1