Main INDEX
Monthly INDEX
PREV
NEXT
User name W. Korsch, JP. Chen
Log entry time 13:12:50 on July13,2001
Entry number 65952
keyword=Access: Opened 3He bottle, reattached TC
11:30 access to Hall
a) Opened 3He bottle for reference cell system.
Pressure reading before opening the bottle: ~100 psi
Pressure reading after opening the bottle: 150 psi
JP tried to reduce the pressure slightly, but it's not clear by how much. It's probably
still around 150 psi.
b) Reattached the thermocouple to oven heater. Attached TC to heater element
that's is hooked up to the feed back circuit (not the one that's connected to
the Variac). Did try to attach it at the transition between the target assembly plate
(on top of the coils HH coils) and the bottom of the thermo-insulation.
Reading upstairs is now about 94 deg C.