• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 19:11:10 on July 13, 2001

    Entry number 66006

    keyword=Start_Run_21002,Run_type=other,beam_energy=5.7,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=charge asym calibration,daq_mode=one HRS daq,leftarm_p=1320,leftarm_theta=35,rightarm_p=1320,rightarm_theta=35,target_halfwaveplate=out,target_name=TIilghman,target_polarization=,target_type=Empty
    Beginning-of-run EPICS data for Run Number 21002 at Fri Jul 13 19:10:50 EDT 2001
    ; RIGHT SPECTROMETER
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string.
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 to measure efficiency
    ;
    ps1=1,ps2=1,ps8=65535
    
    
     Right Arm Q1 power supply current : 992.705
    Right Arm Q1 momentum : 1.3202
    Right Arm Q1 gauss meter : -0.024795
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 568.138
    Right Arm Q2 momentum : 1.32012
    Right Arm Q2 gauss meter : 0.2986
    Right Arm Q2 power supply polarity : 0
    Right Arm D1 power supply current : 453.55
    Right Arm D1 momentum : 1.32
    Right Arm D1 NMR : 0.489836
    Right Arm Q3 power supply current : 525.342
    Right Arm Q3 momentum : 1.32026
    Right Arm Q3 gauss meter : 0.2355
    Right Arm Q3 power supply polarity : 1
    Left Arm Q1 power supply current : 992.845
    Left Arm Q1 momentum : 1.31969
    Left Arm Q1 gauss meter : -0.08397
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 568.295
    Left Arm Q2 momentum : 1.31977
    Left Arm Q2 gauss meter : 0.3001
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 442.065
    Left Arm D1 momentum : 1.32001
    Left Arm D1 NMR : 0.488601
    Left Arm Q3 power supply current : 525.633
    Left Arm Q3 momentum : 1.32029
    Left Arm Q3 gauss meter : -0.2626
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 11.6235
    Current on Unser monitor : 18.4546
    Current on Upstream bcm : 11.5516
    Current on Downstream bcm : 11.7633
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) :
    Beam energy : 5738.42
    MBSY1c magnet current (amp) : 239.881
    Radiator 5V Linear Supply : 0.002442
    Radiator Encoder : 0
    Right Arm Arm Collimator : 0.865479
    Left Arm Arm Collimator :
    HacR_HPE1313A:0_Ch58 : -0.517578
    HacR_HPE1313A:0_Ch55 : 22.9492
    HacR_HPE1313A:0_Ch54 : -0.908691
    HacR_alignROLL : -0.378477
    HacR_alignPITCH : 0.06968
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.164551
    HacL_HPE1313A:0_Ch55 : 23.877
    HacL_HPE1313A:0_Ch54 : -0.159668
    HacL_alignROLL : 0.0396769
    HacL_alignPITCH : 0.125181
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 35
    Right Arm Angle Vernier : -34
    Right Arm Scattering Angle : 34.9995
    Left Arm Angle Floor Angle : 35
    Left Arm Angle Vernier : 31
    Left Arm Scattering Angle : 35.004
    Wien angle : CAC: UDP send error = "Connection refused"
    Helicity Mode ON/OFF Random/Toggle :
    Wien BDL :
    Wien field :
    Laser attenuation Hall A :
    Laser power Hall A : CAC: UDP send error = "Connection refused"
    Half-wave plate (off=out) : CAC: UDP send error = "Connection refused"
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.769
    Survey Y offset bpmB : -1