Main INDEX
Monthly INDEX
PREV
NEXT
User name Kelly
Log entry time 16:02:51 on July24,2001
Entry number 67425
keyword=day shift summary
Day shift summary 7/24/01
====================
0800: start shift with first run of new configuration in progress.
1010: the beam position sometimes changes after trips and must be reset. The Compton group also wants a scan, their trajectory needs improvement
1015: run end failed on right arm, ROC15 hung again.
1025: target polarization measurement, NMR=39.3%, EPR=39.6%
1105: resume production
1105: right DAQ did not start. End run 2226/21226, terminate 3 DAQs, kcoda, reboot all components, restart runcontrol. Right DAQ still did not start for run 21227. Have triggers on xscaler. Call in expert.
1140: beam has been off for 15 minutes. MCC reports BCM trips and will take beam to check orbits. Bob arrives to check DAQ problems.
1200: DAQ problem due to runend process stalled, but not removed by kcoda. Fixed by adding that process to the kcoda list of condemned processes. Runs 226-234 are junk. Still no beam.
1210: beam back, resume production with run 2235/21235.
1440: MCC takes beam for Hall B optics study, expected to be 1/2 hour. Do target polarization measurement. NMR=37.7%
1530: resume production, but beam unstable.
Configuration: 3He 270 deg, beam and target halfwave plates out, toggle mode
.
runs..................left....right......total
2224/21224....6121....5853....12.0k
2225/21225....5629....3759....21.4k
2235/21235....5229....5100....31.7k
2236/21236....2486....2360....36.5k