• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name R. Michaels

    Log entry time 09:45:08 on July25,2001

    Entry number 67509

    This entry is a followup to: 67492

    keyword=re: charge asy algorithm

    I agree about the improvements, and they will be ready in a few days, we hope.
    The new algorithm, which is in the works (thanks, Antonin Vacheret)
    will do the following better things.
    1) Runs online (ET system) constantly and produces feedback every
    10 minutes. This is the optimum timescale given the noise structure.
    2) Each feedback value is based on 2 passes through the data. One pass
    to get the rough average and sigma, and the other to cut out the
    beam trips by rejecting tails. This is essentially what Seonho suggests.
    This could also be done on the existing algorithm, but we're close to
    releasing the new one anyway. It looks like the ramp up time is bigger
    than what the code assumes.