• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 14:28:20 on July 25, 2001

    Entry number 67547

    keyword=Start_Run_21257,Run_type=other,beam_energy=5.7,beam_halfwaveplate=out,beam_polarization=83.0,beam_raster=on,comment_text=carbon foils/BeO 25uA false asymmetry check lambda/2 out,daq_mode=both HRS daq,leftarm_p=1320,leftarm_theta=35,rightarm_p=1320,rightarm_theta=35,target_halfwaveplate=out,target_name=Tilghman,target_polarization=32.3,target_type=BeO Carbon foils
    Beginning-of-run EPICS data for Run Number 21257 at Wed Jul 25 14:27:59 EDT 2001
    ; RIGHT SPECTROMETER
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string.
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 to measure efficiency
    ;
    ps1=1,ps2=1,ps8=65535
    
    
     Right Arm Q1 power supply current : 992.495
    Right Arm Q1 momentum : 1.31992
    Right Arm Q1 gauss meter : -0.0248
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 568.001
    Right Arm Q2 momentum : 1.3198
    Right Arm Q2 gauss meter : 0.2986
    Right Arm Q2 power supply polarity : 0
    Right Arm D1 power supply current : 451.629
    Right Arm D1 momentum : 1.32
    Right Arm D1 NMR : 0.489836
    Right Arm Q3 power supply current : 525.366
    Right Arm Q3 momentum : 1.32032
    Right Arm Q3 gauss meter : 0.2354
    Right Arm Q3 power supply polarity : 1
    Left Arm Q1 power supply current : 992.95
    Left Arm Q1 momentum : 1.31983
    Left Arm Q1 gauss meter : -0.08406
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 568.308
    Left Arm Q2 momentum : 1.31981
    Left Arm Q2 gauss meter : 0.2991
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 441.29
    Left Arm D1 momentum : 1.31999
    Left Arm D1 NMR : 0.488594
    Left Arm Q3 power supply current : 525.681
    Left Arm Q3 momentum : 1.32041
    Left Arm Q3 gauss meter : -0.2627
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 24.9211
    Current on Unser monitor : 30.5627
    Current on Upstream bcm : 24.7242
    Current on Downstream bcm : 25.0984
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) : CAC: UDP send error = "Connection refused"
    Beam energy : 5738.42
    MBSY1c magnet current (amp) : 239.881
    Radiator 5V Linear Supply : 0
    Radiator Encoder : 0
    Right Arm Arm Collimator : 0.86543
    Left Arm Arm Collimator : 0.868799
    HacR_HPE1313A:0_Ch58 : -0.523438
    HacR_HPE1313A:0_Ch55 : 22.1191
    HacR_HPE1313A:0_Ch54 : -0.911621
    HacR_alignROLL : -0.382327
    HacR_alignPITCH : 0.0636732
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.167969
    HacL_HPE1313A:0_Ch55 : 23.1934
    HacL_HPE1313A:0_Ch54 : -0.164062
    HacL_alignROLL : 0.0348237
    HacL_alignPITCH : 0.121677
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 35
    Right Arm Angle Vernier : -34
    Right Arm Scattering Angle : 34.9994
    Left Arm Angle Floor Angle : 35
    Left Arm Angle Vernier : 31
    Left Arm Scattering Angle : 35.0041
    Wien angle :
    Helicity Mode ON/OFF Random/Toggle : CAC: UDP send error = "Connection refused"
    Wien BDL :
    Wien field :
    Laser attenuation Hall A :
    Laser power Hall A :
    Half-wave plate (off=out) : CAC: UDP send error = "Connection refused"
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.769
    Survey Y offset bpmB : -1