• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 16:10:40 on August 2, 2001

    Entry number 68637

    keyword=Start_Run_2441,Run_type=other,beam_energy=0,beam_halfwaveplate=in,beam_polarization=0,beam_raster=off,comment_text=diskr gate width test,daq_mode=one HRS daq,leftarm_p=1123,leftarm_theta=18.5,rightarm_p=1123,rightarm_theta=18.5,target_halfwaveplate=in,target_name=,target_polarization=0,target_type=Empty
    Beginning-of-run EPICS data for Run Number 2441 at Thu Aug 2 16:10:30 EDT 2001
    ; LEFT SPECTROMETER
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string.
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T4 to measure efficiency
    ;
    ps3=1,ps4=1,ps8=65535
    Right Arm Q1 power supply current : 844.375
    Right Arm Q1 momentum : 1.12294
    Right Arm Q1 gauss meter : -0.02109
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 483.125
    Right Arm Q2 momentum : 1.12259
    Right Arm Q2 gauss meter : 0.254
    Right Arm Q2 power supply polarity : 0
    Right Arm D1 power supply current : 383.574
    Right Arm D1 momentum : 1.123
    Right Arm D1 NMR : 0.416732
    Right Arm Q3 power supply current : 446.848
    Right Arm Q3 momentum : 1.12299
    Right Arm Q3 gauss meter : 0.20023
    Right Arm Q3 power supply polarity : 1
    Left Arm Q1 power supply current : 844.935
    Left Arm Q1 momentum : 1.12309
    Left Arm Q1 gauss meter : -0.07153
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 483.693
    Left Arm Q2 momentum : 1.1233
    Left Arm Q2 gauss meter : 0.2555
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 374.762
    Left Arm D1 momentum : 1.12301
    Left Arm D1 NMR : 0.415747
    Left Arm Q3 power supply current : 447.088
    Left Arm Q3 momentum : 1.123
    Left Arm Q3 gauss meter : -0.2232
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 0.0313319
    Current on Unser monitor : 4.55135
    Current on Upstream bcm : 0.0394199
    Current on Downstream bcm : 0.0232439
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) : 0.00143682
    Beam energy : 5738.42
    MBSY1c magnet current (amp) : 0.0377197
    Radiator 5V Linear Supply : 0
    Radiator Encoder : 0
    Right Arm Arm Collimator : 0.865332
    Left Arm Arm Collimator : 0.868848
    HacR_HPE1313A:0_Ch58 : -0.526855
    HacR_HPE1313A:0_Ch55 : 23.8281
    HacR_HPE1313A:0_Ch54 : -0.805664
    HacR_alignROLL : -0.273396
    HacR_alignPITCH : 0.0623505
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.154297
    HacL_HPE1313A:0_Ch55 : 25.2441
    HacL_HPE1313A:0_Ch54 : -0.0942383
    HacL_alignROLL : 0.101486
    HacL_alignPITCH : 0.137369
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 18.5
    Right Arm Angle Vernier : -16.8
    Right Arm Scattering Angle : 18.6004
    Left Arm Angle Floor Angle : 18.5
    Left Arm Angle Vernier : 48.4
    Left Arm Scattering Angle : 18.6032
    Wien angle : 2.38446
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 18.827
    Wien field : 0.68176
    Laser attenuation Hall A : 0
    Laser power Hall A : 57
    Half-wave plate (off=out) : ON
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.769
    Survey Y offset bpmB : -1