Main INDEX
Monthly INDEX
PREV
NEXT
User name R. Michaels
Log entry time 14:36:20 on August 3,2001
Entry number 68799
This entry is a followup to: 68623
keyword=Asym Gen Results and Time Asy
Results of partial analysis of the run for the latest Asymmetry Generator
test in g2n configuration with random helicity mode (which is how you are
running now). The input asymmetry was kept at -830 ppm, as it was the
smallest I could get from the generator. The negative sign is supressed.
Parity DAQ...................Left Spectrometer.......................Right Spectrometer
..............................20 M Triggers.........Scalers........20 M Triggers.........Scalers
849 +/- 3 ppm.......738.................833 +/- 26...........783.................824 +/- 24
The time asymmetry for recent runs that ran at least 8 minutes (there were not
many yet !) using the 1024 Hz clock and the 1 Mhz scaler looks good, generally
less than 50 ppm. Quoted errors comes from observed fluctuations between runs:
--------------- Time Asymmetries (PPM) --------------
........Left Spectrometer..........................Right Spectrometer
...1024 Hz clock..........1 Mhz................1024 Hz clock............1 Mhz
A = 35 +/- 25 ppm....42 +/- 20............27 +/- 28................25 +/- 15