• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 18:31:57 on August 4, 2001

    Entry number 69210

    keyword=Start_Run_2572,Run_type=elastic,beam_energy=1.197,beam_halfwaveplate=out,beam_polarization=82,beam_raster=on,comment_text=run on the shapiro cell,daq_mode=both HRS daq,leftarm_p=1195,leftarm_theta=18.6,rightarm_p=1195,rightarm_theta=18.6,target_halfwaveplate=out,target_name=shapiro,target_polarization=48,target_type=Polarized He-3 0deg
    Beginning-of-run EPICS data for Run Number 2572 at Sat Aug 4 18:31:50 EDT 2001
    ; LEFT SPECTROMETER
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string.
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T4 to measure efficiency
    ;
    ps3=1,ps4=1,ps8=65535
    Right Arm Q1 power supply current : 898.415
    Right Arm Q1 momentum : 1.1948
    Right Arm Q1 gauss meter : -0.02243
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 514.217
    Right Arm Q2 momentum : 1.19483
    Right Arm Q2 gauss meter : 0.2703
    Right Arm Q2 power supply polarity : 0
    Right Arm D1 power supply current : 409.181
    Right Arm D1 momentum : 1.195
    Right Arm D1 NMR : 0.44345
    Right Arm Q3 power supply current : 475.313
    Right Arm Q3 momentum : 1.19453
    Right Arm Q3 gauss meter : 0.213
    Right Arm Q3 power supply polarity : 1
    Left Arm Q1 power supply current : 899.01
    Left Arm Q1 momentum : 1.19497
    Left Arm Q1 gauss meter : -0.07605
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 514.497
    Left Arm Q2 momentum : 1.19484
    Left Arm Q2 gauss meter : 0.2719
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 399.095
    Left Arm D1 momentum : 1.19499
    Left Arm D1 NMR : 0.442368
    Left Arm Q3 power supply current : 475.779
    Left Arm Q3 momentum : 1.19507
    Left Arm Q3 gauss meter : -0.2376
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 1.70558e-304
    Current on Unser monitor : 6.83334
    Current on Upstream bcm : 1.693e-304
    Current on Downstream bcm : 1.71815e-304
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) : 0.874283
    Beam energy : 1197.93
    MBSY1c magnet current (amp) : 49.6474
    Radiator 5V Linear Supply : 0.00732601
    Radiator Encoder : 0
    Right Arm Arm Collimator : 0.865381
    Left Arm Arm Collimator : 0.868408
    HacR_HPE1313A:0_Ch58 : -0.525879
    HacR_HPE1313A:0_Ch55 : 22.998
    HacR_HPE1313A:0_Ch54 : -0.822266
    HacR_alignROLL : -0.291151
    HacR_alignPITCH : 0.0621147
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.154785
    HacL_HPE1313A:0_Ch55 : 24.707
    HacL_HPE1313A:0_Ch54 : -0.0976562
    HacL_alignROLL : 0.0970543
    HacL_alignPITCH : 0.135171
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 18.5
    Right Arm Angle Vernier : -16.8
    Right Arm Scattering Angle : 18.6001
    Left Arm Angle Floor Angle : 18.5
    Left Arm Angle Vernier : 48.4
    Left Arm Scattering Angle : 18.6033
    Wien angle : 2.38446
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 18.827
    Wien field : 0.68176
    Laser attenuation Hall A : 0
    Laser power Hall A : 57
    Half-wave plate (off=out) : OFF
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.769
    Survey Y offset bpmB : -1