    User name ransome

    Log entry time 16:02:44 on August 5,2001

    Entry number 69452

    keyword=day shift summary

    Begin shift with daq problems, doing ep run
    Around 8:30 Mike Memory arrives to check network
    Moved network routers HALLA-CAT and HALLASC-CAT
    from UPS to regular plugs. He said they had rebooted and suspects it was due to a
    problem with UPS. Couldn't find other problems, but not
    all IOC's could be reached from all networks, so there are still
    some problems
    9:40 We try to start a run. Unable to connect TS0 on right arm.
    9:55 Call for entry
    10:50 out of Hall, reset VME crate on lower level of right detector hut
    Reboot all IOC - Run appears to start OK but no events taken in right arm
    reboot adaql2
    11:41 Going again! Running 12C with 5 uA, raster on
    12:00 beam at (-0.2,-1.2), request to be put at (0,0)
    13:05 notice left spectrometer deadtime is fluctuating from 8% up to 80%
    or 100%, run 2613
    13:15 ended run, rebooted sfi2
    13:25 beam off, need to MCC says they need to reset a magnet
    13:46 beam back
    14:00 beam off again, accel. magnet problem again
    14:22 beam back
    14:35 beam off again, MCC says machine dropped to power permit, they
    are investigating
    15:47 beam back, continue with 12C and 5 uA
    15:52 beam off
    15:58 beam back